EasyManua.ls Logo

Zip HydroTap G5 BC100 - Page 28

Zip HydroTap G5 BC100
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
28
Quick Start Installation Guide
807118UK v1.12 12.23 G5 BC Quick Start Guide
SECTION 12: Commissioning
12.5.1 Limescale filter flush
Disconnect the limescale filter OUT hose
from the Command Centre manifold.
Direct it into a sink or suitable container.
Touch green play icon to start filter flush.
12:12 PMLIMESCALE FILTER FLUSH
Step 1.
Disconnect the limescale filter OUT hose
from the manifold inlet.
Step 2.
Place a 15L container under the hose to catch
the water flushed through the filter.
12:12
| |
LIMESCALE FILTER FLUSH
RUNNING.....
Water is now being flushed through the filter.
This process is automatic and will take 7 minutes.
Press pause to pause filter flush.
LIMESCALE FILTER OPTION 12:12 PM
Do you have a limescale filter installed
with your HydroTap ?
NO YES
12:12 PMLIMESCALE FILTER FLUSH
LIMESCALE FILTER HAS BEEN FLUSHED!
Reconnect the limescale filter hose to the manifold.
Once the filter flush is finished, reconnect
the limescale filter OUT hose to the
Command Centre manifold.
Touch the arrow to go to the next screen.
Follow the steps on-screen.
(Selecting NO advances the screen to the next process).
(If optional limescale filter is installed)
IN
OUT
IN OUT
IN OUT