Important Security Instructions
- 3 -
1.2 Installation Cautions
1. The conduits of wires under relay must be matched with metaled conduits, other
wires can use PVC conduits, to prevent failure caused by rodent damage. Although a
control panel is designed with good antistatic, lightning-proof, and
leakage-proof functions, ensure its chassis and the AC ground wire are
connected properly and the AC ground wire is grounded physically.
2. It is recommended not to plug/unplug connection terminals frequently when
the system is energized. Be sure to unplug the connection terminals before
starting any relevant welding job.
3. Do not detach or replace any control panel chip without permission, because
unprofessional operation may cause damage to the control panel.
4. It is recommended not to connect any other auxiliary devices without
permission. All non-routine operations must be communicated to our
engineers in advance.
5. A control panel should not share one power socket with any other
large-current device.
6. It is preferable to install card readers and buttons at heights of 1.4-1.5m above
the ground, but the heights are subject to proper adjustment according to
customers’ usual practice.
7. It is advised to install control panels at places easy of maintenance, like a
weak electric well.
8. It is strongly recommended that the exposed part of any connection terminal
should not be longer than 4mm, and specialized clamping tools may be used
to avoid short-circuit or communication failure resulting from accidental
contact with excessive exposed wires.
9. To save access control event records, read data periodically from control
panels.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ZKTeco C3-400 and is the answer not in the manual?

ZKTeco C3-400 Specifications

General IconGeneral
InterfaceRJ-45 / RS-485
Case designBare
Built-in UPSNo
Number of users30000 user(s)
Maximum number of doors4 door(s)
Switchable current1.5 A
Operating temperature (T-T)0 - 40 °C
Operating relative humidity (H-H)20 - 80 %
Weight and Dimensions IconWeight and Dimensions
Depth90 mm
Width330 mm
Height300 mm
Weight3550 g