Electrical Grounding
is appliance is equipped with a four-prong plug for
your protection against shock hazard and should be
plugged directly into a properly grounded receptacle,
do not cut or remove the prong from this plug.
ELECTRICAL SHOCK HAZARD
Disconnect electrical power at the circuit breaker
box or fuse box before installing the appliance.
Provide appropriate ground for the appliance. Use
copper conductors only.
Failure to follow these instructions
could result in serious injury or death.
Electrical Connection
e appliance shall be connected to a single phase
electric line rated at 120/208Vac or 120/240Vac and
60Hz frequency.
Electric Power Rating:
• 120/240Vac: 12A Max
Heating Elements Power Rating:
• Oven Bake Element=1500 Watt
• Oven Circulation Element=3200 Watt
• Oven Broil Element=2850 Watt
Install suitable electric power supply receptacle con-
nection type NEMA 14-50R able to support a load
of at least 30 A (Per Line) according to local code re-
quirements. For four wires power supply connection
system (see diagram below).
Four-Wire Connection Receptacle
NEMA 14-50R
WARNING!
CAUTION!
Label all wires prior to disconnecting when servicing
controls. Wiring errors can cause improper and danger-
ous operation. Verify proper operation aer servicing.
Check your local code for which of the options be-
low should be used in grounding the receptacle pow-
er supply connections.
Four Wires Connection
• Connect the L1 receptacle terminal to the incom-
ing BLACK electrical supply wore (L1-hot wire).
• Connect the L2 receptacle terminal to the incom-
ing RED electrical supply wire(L2-hot wire).
•
•
Connect the NEUTRA
L receptacle terminal to
the incoming NEUTRAL (WHITE)
electrical supply wire.
Connect the GROUND receptacle terminal in-
coming GROUND (Green) electrical supply wire.
DO NOT USE EXTENSION CORDS WITH
THIS APPLIANCE AS IT MAY RESULT IN
FIRE, ELECTRIC SHOCK OR OTHER TYPES
OF PERSONAL INJURY.
e appliance is equipped at the factory with an
electric supply cord set 4 wires type with ring ter-
minals(L1, L2, N, Ground) suitable for range use
U:/CSA listed type SRDT/DRT 2x6AWG (L1,
L2,)+2x8AWG(N, G) rated 300V, 40 or 50A with
fused plug type NEMA 14-50P, cable length 1.5m;
in case the supply cord set must be replaced, it shall
be replaced with an identical set having the same
technical specs and following carefully the instruc-
tions and diagrams above.
L2 (RED) L2 (RED)
L1 (BLACK)
CABLE FROM
POWER SUPPLY
L1 (BLACK)
G (GREEN)
G (GREEN)
N (WHITE)
N (WHITE)
10