Step 1: PRESSURE REGULATOR
e pressure regulator supplied with the appliance
is a convertible type pressure regulator for use with
Natural Gas at a nominal outlet pressure of 4 w.c. or
LP gas at a nominal outlet pressure of 11” w.c. and it
is pre-arranged from the factory to operate with one
of these gas/pressure as indicated in the labels axed
on the appliance, package and instruction booklet.
To convert the regular for use with other liquid propane
LP gas:
1. Unscrew by hand the upper cap of the regulator,
remove the white plastic attachment from the
e gas conversion procedure for this range
includes:
1. Pressure Regulator
2. Surface Burners
3. Adjustment of Minimum Setting
The
conversion is not complete if all steps are not
completed.
Before performing the gas conversion, locate the
package containing the replacement nozzle has a
number indicating its ow diameter printed on the
body. Consult the table on page 20 for matching noz-
zles to burners.
Save the nozzles removed om the range for future use.
Gas Conversion Procedure
cap, reverse its direction and screw it again rm-
ly against the cap. e white plastic attachment
has arrows indicating the position for natural gas
(NAT) and LP gas (LP).
2. Screw by hand the metal cap in the original posi-
tion on the regulator.
Step 2: SURFACE BURNERS
To
replace the nozzles of the surface burners, li up
the burners and unscrew the nozzles shipped with
the range using a 7 mm (socket wrench).
Replace nozzles using the conversion set
supplied with the range. Each nozzle has a number
indicating its flow diameter printed on the body.
Consult the table on page 19 for matching nozzles
to burners.
Step 3: MINIMUM FLAME ADJUSTMENT
WARNING!
ese adjustments should be made only for use of the
appliance with natural gas. For use with liquid pro-
pane gas, the choke screws must be fully turned in a
clockwise direction.