WARNING!
A manual valve shall be installed in an accessible lo-
cation in the gas line external to the appliance for
the purpose of turning on and shutting o the gas
to the appliance.
Do not use aerosol sprays in the vicinity of this
appliance while it is in operation.
Room Ventilation: An exhaust fan may be used with
the appliance; in each case it shall be installed in
conformity with the appropriate national and local
standards. Exhaust hood operation may aect other
vented appliances; in each case it shall be installed in
conformity with the appropriate national and local
standards.
Type of Gas
is appliance is shipped from the factory for use
with natural gas. For use with propane LP gas please
follow the conversion procedure described on pg. 14.
A step by step conversion procedure is also included
with each set of LP gas nozzles.
Gas Pressure
e maximum inlet gas supply pressure incoming to
the gas appliance pressure regulator is 34PSI (13,8w.
cpr 3,5kPA).
e minimum gas supply pressure for checking the
regulator setting shall be at least 1 w.c (249 Pa)
above the inlet specied manifold pressure to the ap-
pliance (is operating pressure is 4 w.c. (1.00kPa)
for Natural gas and 11 w.c. (2.75 kPa) for LP gas.
Before Installation
is appliance shall only be installed by an autho-
rized professional.
e appliance shall be installed in accordance with
the standards of the country where it will be in-
stalled. e installation of this appliance must con-
form to local codes and ordinances. In the absence of
local codes installation must conform to American
National Standards, National fuel Gas code ANSI
Z223.1-Latest edition/NFPA 54 or B 149.1.
e appliance, when installed, must be electrically
grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical
code, ANSI/NFPA 70.
If local codes permit, a exible metal appliance con-
nections with the new AGA or CGA certied design,
max 5 feet (1,5m) long, 34 I.D. is recommended
for connecting this appliance to the gas supply line.
DO NOT bend or damage the flexible connector
when moving the appliance.
is appliance must be used with the pressure reg-
ulator provided. e regulator must be properly in-
stalled in order to be accessible when the appliance
is installed in its final location. The pressure
regulator must be set for the type of gas to be used.
The pres-sure regulator has 34 female pipe thread.
The appro-priate fitting must be determined based
on the size of your gas supply line, the flexible metal
connector and the shut-off valve.
e appliance must be isolated from the gas supply
piping system by closing its individual manual shut-
o valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than 34
PSI(13,8w.cpr 3,5kPA).
All opening holes in the wall and floor, back and
under the appliance shall be sealed before installa-
tion of the appliance.