PH ERROR pH adjustment has performed 5 cycles with-
out reaching its set point (> 10 hours)
Check the pH in the pool
Calibrate or replace the pH sensor
The pH minus container is empty Replace the container
The peristalc pump is not primed Test the peristalc pump
The pH sensor is dirty, out of calibraon or
not working
Clean and calibrate the sensor
Replace the pH7.5 buer soluon if necessary
The pool size seng is too small Check the selected pool size
The peristalc pump has not been operated
for a total of more than 72 hours
The pH in the pool does not need to be corrected
ACL HIGH The measured Redox potenal is more than
150 mV above the set point (the chlorine
level may be excessive)
Clean and calibrate the sensors
Wait for the error message to disappear (no chlorine
producon)
The pH is too low Ensure that the stabilizer is less than 30 ppm
Reduce the ACL set point
Ensure the water is not too mineral (bore-hole water
prohibited)
ACL ERROR ACL adjustment has allowed chlorine pro-
ducon for a total of more than 30 hours
without reaching the ACL set point
Check the pH in the pool
Clean and calibrate the sensors
Replace the buer soluons if necessary
Replace the sensors
Use the 'boost' mode, if necessary
The chlorinator has not produced chlorine
for a total of more than 30 hours
Check the chlorine level in the pool
Clean and calibrate the sensors
Replace the buer soluons if necessary
Replace the sensors
To cancel the 'PH ERROR' and 'ACL ERROR' error messages, press for 3 or 4 seconds when the message ap-
pears.
Other codes are only informaon messages that disappear by themselves when operang condions return to
opmum values.