3
© Copyright 2016 Zoeller
®
Co. All rights reserved.
MODELS: 507-C 507-D 507-E 507-F
ITEM DESCRIPTION QTY
4/96
thru
10/05
11/05
thru
9/11
10/11
thru
10/13
11/13
thru
Current
1 DC backup pump 1 017198 017198 017198 017198
2 Plastic battery box and cover 1 10-0764 10-0764 10-0764 10-0764
3 DC control charger with terminals 1 152899 152899 152899 152899
4 “Off”/”On” oat switch 1 017197 017197 017197 017197
5 1½" x 5" long PVC pipe nipple 1 005639 N/A N/A N/A
6 Check valve (2) REV C - (1) REV D 005636 005636 019768 019768
7 Reducer hose coupling and clamp 1 30-0188 N/A N/A N/A
8 1¼" x 1" PVC reducer tting 1 005642 N/A N/A N/A
9 1" pipe to hose adapter elbow 1 005643 N/A N/A N/A
10 1" hose coupling and two clamps 1 005703 N/A N/A N/A
11 1½" PVC pipe tee 1 005645 005645 005645 005645
12 1½" 90 degree PVC pipe elbow 1 005644 N/A N/A N/A
13 1¼" x 1¼" PVC coupling 1 009129 N/A N/A N/A
14
Pump mounting kit, includes brkt, S.S. worm drive
clamp, two #10-24 screws and washers.
1 005704 N/A N/A N/A
15 Cable tie 1 005868 N/A N/A N/A
16 Anchors, wall 2 009691 009691 009691 N/A
17 Bracket, control mounting 1 007779 007779 007779 N/A
18 1½" x 1½" PVC coupling 1 N/A 009746 N/A N/A
19 Clamp, H28 SS / zinc-plated screw 1 012724 012724 012724 012724
20 Fuse, AGC - 15 amp 1 N/A 012352 012352 012352
REPLACEMENT PARTS LIST
The DC emergency pump is designed as a backup to your primary sump pump during unexpected power outages or primary pump failure. The
DC pump, electronic controls and all the parts required for installation are included except the battery which is supplied by the user. The system
is designed for installation in sumps with minimum of 18" diameter and 24" deep. For 18" x 22" applications, consult factory.
DESCRIPTION
TROUBLESHOOTING INFORMATION, continued
9. Alarm does not sound when pump runs.
(a) Pumps needs to run for 3 or more seconds before alarm
sounds.
(b) Be sure alarm hasn't been silenced. Quickly press and release
reset button.
(c) Inspect the connection between the green wire and the blue
connecter on the white wire. Verify that the metal spade has not
"missed" its target.
2
12 VOLT BATTERY
SUPPLIED BY USER
1
19
4
20
3
6
11
SK2981
The DC emergency pump system requires a good quality, 12 volt
battery to obtain maximum pumping time during a power outage.
A deep-cycle, 12 volt, 105 amp-hour marine battery or larger is
recommended and will provide approximately 7½ hours of continuous
pumping time in a sump pump installation with 8' of head pressure. In
most installations the pump runs intermittently and the battery life is
extended accordingly. Batteries with top terminals are recommended
for ease of installation. These batteries contain acid and proper
precaution must be taken when handling. Battery box will accomodate
a maximum battery size 13½" length x 7" width x 9½" height.
BATTERY SELECTION

Other manuals for Zoeller Basement Sentry Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zoeller Basement Sentry Series and is the answer not in the manual?

Zoeller Basement Sentry Series Specifications

General IconGeneral
BrandZoeller
ModelBasement Sentry Series
CategoryWater Pump
LanguageEnglish

Related product manuals