16
Special Start-up
There are some methods to start up the G2.1u for service.
To start up the unit, set the [POWER] switch to “ON” while holding any keys.
The following table shows which keys are held down.
Keys held down Purposes
Play Mode None Normal operation
Initialization [STORE] Recovering factory default
Test Mode [TYPE +] + [TYPE -] + [RHYTHM] Function test
Data transfer [STORE] + [RHYTHM] Backing up user’s data
Version [UP] Checking software version
Revision [DOWN] Checking software revision
● Play Mode
Normal operation.
See the operation manual.
● Initialization
This startup recovers the factory default condition.
Refer to page 17.
● Test Mode
This startup is used for the function Test.
Refer to page 13-15.
● Data transfer
This startup backs up the user’s effect patch data.
Refer to page 11, 12.
● Version
This startup indicates the software version number.
The indication “0003” appears on the display. (depend on circuit versions)
● Revision
This startup indicates the software revision number.
The indication “9005” appears on the display. (As of October, 2005)