Size: 1 byte dec.
Power Report Frequency
Parameter 171: Choose how often you want your Power Switch to report power consumption (W) to your controller
and associated device. The number entered as value corresponds to the number of seconds. So if 30 is entered by
default, the Power Switch will report power consumption every 30 seconds.
Values: 5 – 2678400; 0 – disabled (it will not report power consumption); 30 – default setting
Size: 4 byte dec.
Energy Report Frequency
Parameter 172: Choose how often you want your Power Switch to report energy usage (KWH) to your controller and
associated device. The number entered as value corresponds to the number of seconds. So if 300 is entered by
default, the Power Switch will report energy usage every 300 seconds (5 minutes).
Values: 5 – 2678400; 0 – disabled (it will not report energy usage); 300 – default setting
Size: 4 byte dec.
Voltage Report Frequency
Parameter 173: Choose how often you want your Power Switch to report voltage (V) to your controller and
associated device. The number entered as value corresponds to the number of seconds.
Values: 5 – 2678400; 0 – disabled (default – it will not report voltage levels)
Size: 4 byte dec.
Electricity Report Frequency
Parameter 174: Choose how often you want your Power Switch to report levels of electrical current (A) to your
controller and associated device. The number entered as value corresponds to the number of seconds.
Values: 5 – 2678400; 0 – disabled (default – it will not report electrical current levels)
Size: 4 byte dec.
WARNING
This product should be installed indoors upon completion of any building renovations
Prior to installation, the device should be stored in a dry, dust-and-mold-proof place
Do not install the Power Switch in a place with direct sun exposure, high temperature or humidity
Keep away from chemicals, water, and dust
Ensure the device is never close to any heat source or open flame to prevent fire
Ensure the device is connected to an electric power source that does not exceed the maximum load power
No part of the device may be replaced or repaired by the user
Z-WAVE PLUS CERTIFIED
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other
manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters
regardless of vendor to increase reliability of the network.
ETL CERTIFIED
This is an ETL certified device. ETL, just like UL, is a Nationally Recognized Testing Laboratory. The ETL mark is
proof of product compliance to North American safety standards.