GSM module, use G##, where ## is number of GSM module.
Tariff – use this parameter to specify the Tariff number.
Time from – set the beginning value of the time interval (hh:mm) for the
selected rule.
Time to – set the end value of the time interval (hh:mm) for the selected rule.
Day – define a day in the week on which the rule shall be applied (1= Monday,
…, 7 = Sunday).
Clip table structure:
Prefix Company
Change
prefix
Delete
last
Out
group
Time
from
Time
to
Day
605205697% 1 0 129 00:00 12:00 1234567
605205697#% 4 1 9 12:00 24:00 1234567
605% 1 #31# 0 129 00:00 24:00 1234567
605% 2 +420 0 349 00:00 24:00 1234567
0605% 3 -#31# 0 59 00:00 24:00 1234567
608% 1 #31#+420 0 0 00:00 24:00 1234567
% 1 0 9 00:00 24:00 1234567
% 100 0 G10 00:00 24:00 1234567
% 101 0 G1 00:00 12:00 1234567
% 101 0 G12 12:00 24:00 1234567
Black & White Tables
Set the rules to disable routing for calls that failed to meet the set parameters before,
such as unconnected calls, short calls, rejected calls, and so on.