EasyManua.ls Logo

3Com WL-561 - Troubleshooting; Diagnosing Problems

3Com WL-561
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Connecting through the Com Port
45
Connecting
through the Com
Port
Instead of using an IP address to configure the Access Point a Null
modem cable, connected to the AP’s serial port, can be used.
In your terminal settings ensure that the following configuration is
met:
Bits per Second – 9600
Data Bits – 8
Parity – None
Stop bits – 1
Flow Control - none
Once connected enter the user name and password. The default
values are as follows:
Username: admin
Password: password
Once logged in, type”?” for a list of commands.
Restoring factory
settings
The Access Point can be reset to the default factory settings either
through the web browser (see Backup/ Restore Settings) or
manually.
To restore the settings manually, insert a pointed object (such as
the end of a straightened paper clip) into the reset hole on the
back of the Access Point, and hold for five seconds.
RESET
RESET
Reset Hole