Gas/Vapour Filter Classes
The 6000 Series gas/vapour ¿lters are also classi¿ed, into one of two classes, depending on their capacity to remove
contaminants from the inhaled air
Filter Model
3M™ 6091 A1P3 R
A1B1E1K1P3
R + form
A2P3 R
A1E1HgP3 R
AXP3 NR
A2B2E2K2Hg
P3 R + form
Organic vapours with boiling point >65°C (with good warning properties) as speci¿ed by the manufacturer and
mercury vapour, chlorine, acid gases and particulates. If used for Hg, maximum use time = 50 hours.
Organic vapours with boiling point >65°C (with good warning properties) as speci¿ed by the manufacturer and
particulates
Organic vapours with boiling point >65°C (with good warning properties) as speci¿ed by the manufacturer and
particulates
Note: AX Àlters are for single use only
The ¿lter should not be used on a second shift even if these maximum usage times are not exceeded. When changing ¿lters ensure that both ¿lters are
replaced simultaneously.
Combination organic vapours (boiling.point > 65°C (with good warning properties), inorganic gases, acid gases,
ammonia and formaldehyde up to 10 ppm and particulates
Organic vapours (b.pt>65°C (with good warning properties), inorganic gases, acid gases, ammonia, formaldehyde
up to 10 ppm, mercury vapour and particulates. If used for Hg, maximum use time = 50 hours.
Organic vapours with boiling point <65°C (with good warning properties) as speci¿ed by the manufacturer and
particulates
3M™ 6092
3M™ 6095
3M™ 6096
3M™ 6098
3M™ 6099
ClassiÀcation
Gas Filter Class Maximum use concentration with 3M™ Half mask
Maximum use concentration with 3M™ Full Face mask
Particulate Filter Class
WEL = Workplace Exposure Limit
Maximum use concentration with 3M™ Half mask
Maximum use concentration with 3M™ Full Face mask
Brown
Organic vapours with boiling point >65°C (with good warning properties) as speci¿ed by the manufacturer
Inorganic Gases & Vapours (with good warning properties) as speci¿ed by the manufacturer
Acid Gases (with good warning properties) as speci¿ed by the manufacturer
Ammonia and Organic Ammonia derivatives (with good warning properties) as speci¿ed by the manufacturer
Organic vapours with boiling point equal or less than 65°C (with good warning properties) as speci¿ed by the
manufacturer
10 x WEL or 1000 ppm (0.1% vol) whichever is lower
20 x WEL or 1000 ppm (0.1% vol) whichever is lower in negative
pressure mode
20 x WEL or 5000 ppm (0.5% vol) whichever is lower in negative
pressure mode
10 x WEL or 5000 ppm (0.5% vol) whichever is lower
20 x WEL 40 x WEL
Formaldehyde vapour
Mercury vapour
Solid and non-volatile liquid aerosols
Grey
Yellow
Green
Olive greenFormaldehyde
Brown
Red
White
Type of Contaminant
Filter Type Colour Code
Type of Contaminant
]
End of Shelf Life
)
For Single Use Only
(
Maximum Use Time 50 hours
:
Name and address of Manufacturer
J
Dispose of in accordance with local regulations
When stored as stated, the expected shelf life of the product is 5 years from date of manufacture. End of shelf life (use-by) date is marked on the product and
packaging. The original packaging is suitable for transporting the product throughout the European Union.
R = Reusable
NR = Non reusable (single shift use only)
TECHNICAL SPECIFICATION
3M combination ¿lters generally protect against either single or multiple gas/vapour type(s) and against particulates.