3M
™
 Advanced Systems Tester 900AST Series
19
  Resistance
This function measures the resistance between the 
Red and Black test leads. It is also the entry point 
for accessing the Soak Test and Contact Resistance 
measurements.
The “V” in the upper right corner of the screen 
indicates that the resistance measurement is 
compensating for any foreign voltage on the line. 
Press the 
 key to remove the voltage 
compensation. Use this mode only if you have 
first determined there is no DC voltage on the 
conductor (by using the Voltage function). The non-
compensated measurement is slightly faster, but it is 
not as accurate if there is voltage on the conductor.
The resistance measurement can be affected by 
moisture on the test lead contacts or their access 
points.  For the most accurate measurement make 
sure that these areas are dry.