-/ EN 61000-6-2 standard for electromagnetic compatibility, EMC Immunity (the ability of the
equipment to function in an environment where there is electromagnetic radiation from other
sources)
Nominal protection factor (TH2) 50
Assigned protection factor (APF)
- For UK - APF from BS4275. 20
Manufacturer’s minimum design flow rate: 160 l/min
Nominal airflow: app. 170 l/min
Airflow Plus: app. 200 l/min
Headband size 55-63 cm
Belt size 75-127 cm
Operating temperature -5°C to +55°C
Weight, welding head top Speedglas 9002V, incl. breathing tube: 830 g
Weight, welding head top Speedglas 9002X, incl. breathing tube: 860 g
Weight, Adflo unit (incl. P-filter) 1160 g
Battery life: app. 500 charges
Operation duration and combinations of turbo equipment:
** to achieve conformity with EN 12941 the heavy-duty battery should be used
Symbols:
= Read instructions before use
= Expiry date year/month
0194 = Identification code for approved test authority. See approvals (chapter 2).
1ï
11
1
2
3
4
5
6
7
8
Battery
Combination
Standard
Heavy-
duty
Particle
filter
Particle
+ gas filter
(A1B1E1)
170 l/min
200 l/min
According
to
EN 12941
Expected
operation
time
Filter Flow Operation time
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
8 h
5-6 h
12-14 h
10 h
3-5 h
3-4 h
8 h
5-6 h
4 h
4 h
4 h
4 h
**
**
4 h
4 h