6.0 MAINTENANCE, SERVICING, STORAGE
6.1 CLEANING AND MAINTENANCE: Clean the horizontal lifeline
system with water and a mild detergent. Wipe dry with a clean,
dry cloth and hang to air dry. Do not force dry with heat. An
excessive build-up of dirt, paint, etc. may prevent the system
from working properly, and in severe cases, weaken the rope. A
lubricant may be applied to the moving parts of the rope tensioner.
Do not allow lubricant to contact the rope tensioner teeth.
6.2 STORAGE: Store this horizontal lifeline system in a clean, dry
environment, out of direct sunlight. Avoid areas where chemical
vapors are present. Thoroughly inspect the system after extended
storage.
6.3 USER EQUIPMENT: Maintain, service, and store user equipment
according to manufacturer’s instructions.
7.0 SPECIFICATIONS
7.1 MATERIALS:
Rope Tensioner: Steel, plated
O-rings: Alloy steel, plated
Lifeline Rope: 11/16 in. nylon, static kernmantle, breaking
strength: 12,000 lb.
Rope Tensioner Strap: Polyester/Nylon
Snap Hooks: Alloy steel, plated
Carabiners: High tensile alloy steel, plated
Tie-off Adaptor: Polyester web, plated alloy steel hardware