'NOTE:
When
both
REC
and
PLAY
meter
switches
are
simultaneously
depressed,
the
metering
circuits
will
"default",
and
indicate
the
same
meter
function
indicated
when
only
the
REC
switch
is
depressed.
F.
OPERATIONAL
OPTIONS
Delta
Series
units
may
be
operationally
config
ured
to
perform
various
tasks
depending
on
your
specific
needs.
Special
functions
are
outlined
below:
1.
READY
LAMP
FLASH
The
ready
lamp
may
be
programmed
to
flash,
giving
a
visual
indication
of
a
cartridge
that
has
been
stopped.
A
fast
flash
indicates
a
cartridge
that
has
been
stopped
by
the
operator
using
the
Stop
Switch.
A
slow
flash
indicates
a
cartridge
has
stopped
by
the
1
kHz
cue
tone.
When
units
are
programmed
to
flash,
the
flashing
Ready
may
be
"reset"
to
continuous
Ready
by
momentarily
pressing
the
Stop
switch.
This
jumper
is
located
on
the
Reproduce
Logic
Board.
Jumper
Flash
Option
"IN"
Not
Active
"OUT"
Active
2.
REPEAT
PLAY
LOCKOUT
This
programmable
option
inhibits
playing
the
same
cartridge
twice
in
a
row.
In
other
words,
once
a
cartridge
has
played
and
stopped,
it
may
not
be
restarted
until
it
is
removed
from
the
deck,
and
reinserted.
This
prevents
replay
of
the
same
program
mate
rial.
This
jumper
is
located
on
the
Reproduce
Logic
Board.
Jumper
Repeat
Play
Lockout
"IN"
Enabled
"OUT"Disabled
3.
E.O.M.
HIGH
SPEED
RECUE
May
be
jumpered
so
that
neither,
either,
or
both
the
secondary
(150
Hz)
and
tertiary
(8
kHz)
cue
tone
detectors
cause
the
end-of-message
high
speed
recue
to
occur.
This
jumper
is
located
on
the
Play
Amp
and
Cue
Detector
Board.
4.
REPRODUCE
AMPLIFIER
LEVEL
Provides
out
put
level
range
for
preservation
of
best
signal-
to-noise.
5.
REPRODUCE
OUTPUT
IMPEDANCE
600
ohms,
balanced
transformer
is
standard.
Refer
to
mainframe
schematics
for
information
regard
ing
150
ohm
balanced.
6.
BALANCED
TRANSFORMERLESS
(ACTIVE)
OUT
PUT
All
Delta
Series
units
may
be
operated
in
a
transformerless
(active)
output
stage
configu
ration
for
improved
transient
response.
The
high
slew
rate
of
the
output
stages
may
be
utilized
to
provide
the
best
possible
audio
response,
in
par
ticular
at
the
extreme
ends
of
the
audio
band.
When
output
transformers
are
removed,
DC
isolation
between
the
Delta
output
stage
and
connected
equipment
should
be
maintained.
This
is
accomplished
by
inserting
a
220
mfd
non
polarized
capacitor
in
each
output
leg,
(+)
and
(-).
ITC
provides
an
assembly
to
readily
convert
any
Delta
Series
output
to
balanced
transformer
less.
Delta
I.
II
Audio
Output
Board
831-0252-003
831-0252-013
831-0252-023
831-0252-033
Mono,
w/transformer
Stereo,
w/transformer
Mono,
w/o
transformer
Stereo,
w/o
transformer
Delta
III
Audio
Output
Board
831-0254-003
831-0254-013
831-0254-023
831-0254-033
Mono,
w/transformer
Stereo,
w/transformer
Mono,
w/o
transformer
Stereo,
w/o
transformer
7.
RECORDER
INPUT
IMPEDANCE
20
K
ohms
bridging
is
standard.
The
input
may
be
termi
nated
by
a
150
ohm
or
600
ohm
resistor
by
adding
a
jumper
to
each
input
channel.
The
D-IV
mainframe
has
this
jumper
already
in
place.
Refer
to
the
Delta
IV
input
transformer
board
drawings
for
exact
location.
8.
INPUT
LEVEL
STRAPPING
Input
straps
are
pro
vided
to
select
the
nominal
input
level
range,
to
insure
best
overall
signal-to-noise
is
preserved,
and
to
set
the
nominal
position
of
the
front
panel
level
controls.
Jumpers
are
located
in
the
Delta
IV
mainframe.
9.
DIFFERENTIAL
(TRANSFORMERLESS,
BALANCED)
INPUT
Input
transformers
(standard)
may
be
removed
in
order
to
operate
the
Delta
IV
record
amplifier
in
a
true
differential
input
configura
tion.
High
performance
op-amp
record
ampli
fier
input
sections
permit
this
user
option.
When
operating
in
the
differential
input
mode,
users
should
be
cautious
to
insure
that
no
DC
poten
tial,
or
AC
ground
loops
exist
before
attempting
connection.
Removal
of
the
input
transformer
eliminates
the
DC
protection
characteristics
(iso
lation)
offered
by
the
transformer.
Once
the
transformers
have
been
removed,
wire
jumpers
2-8