ence
tone
(160
nWb/m)
used
on
the
1975
NAB
standard
alignment
tape.
c.
It
cue
level
adjustment
is
required,
turn
trim
mer
R1231,
located
on
the
Recorder
Logic
Control
PC
Board,
until
the
Primary
cue
tone
is
equal
to
the
NAB
standard
reference
tone
of
1
kHz
at
160
nWb/m.
NAB
Cue
Tone
Level
Standards
(1976)
Referenced
to
160
nWb/m
Nominal
Minimum
Maximum
1
kHz
0
-3
+
1
150
Hz
+6
+3
+7
8
kHz
-10
-13
-9
d.
Return
the
left
program
playback
and
cue
playback
head
cables
back
to
their
original
locations.
6.
Meter
Calibration
The
following
adjustments
are
made
with
multi
turn
potentiometers
located
on
the
Record/Me-
ter
Amp
PC
Board.
Potentiometers
are
identified
on
the
small
sticker
applied
to
the
underside
of
the
top
cover
(lid).
a.
Program
Play
Select
the
PLAY
meter
switch
position.
Connect
a
600
ohm
load
across
the
left
or
mono
program
playback
output
terminals.
Insert
and
play
an
NAB
standard
reference
level
tape
(1
kHz
at
160
nWb/m
recorded
level
1975
standard).
Adjust
R10
19
for
a
0
VU
indication.
Repeat
this
procedure
for
the
right
channel
if
the
machine
is
stereo.
Use
R1015
for
cali
brating
the
right
PGM
Play
meter
for
0
VU.
b.
Normal
Record
Select
the
PGM
PLAY
meter
switch
position.
Place
the
machine
into
the
recording
mode.
Select
the
REC
meter
switch
position
and
observe
the
level(s).
Use
R1022
to
obtain
a
0
VU
indication
for
the
left
channel
(mono).
Use
R10
18
to
adjust
the
right
meter
to
read
0VU.
c.
Program
Bias
Select
the
PGM
Bias
meter
switch.
Insert
an
erased
cartridge,
press
REC
and
START.
Adjust
the
left
channel
(mono)
program
bias
trimmer
R1020
for
a
0
VU
reading
on
the
left
channel
meter.
Repeat
this
same
procedure
for
the
right
channel
using
trimmer
R10
16.
d.
Cue
Bias'
Select
the
CUE
BIAS
meter
switch.
Insert
an
erased
cartridge
and
press
START.
While
pressing
and
holding
the
TER
(ter
tiary)
cue
switch,
adjust
potentiometer
R10
17
for
a
0
VU
reading
on
the
front
panel
meter
(right
meter).
e.
Cue
Play'
Select
the
CUE
PLAY
meter
switch.
Insert
and
erased
cartridge
tape
and
press
START.
Press
the
1
kHz
CUE
REC
switch.
A
meter
deflection
for
approximately
3/4
of
a
sec
ond
in
length
will
be
observed.
The
point
at
which
the
meter
settles
in
the
last
1/4
second
is
the
point
at
which
0
VU
should
be
calibrated.
Adjust
R1021
to
calibrate
the
Cue
play
metering
to
read
0
VU.
'NOTE:
Since
the
Delta
IV
features
combina
tion
metering
of
Cue
Bias
and
Cue
Play,
pay
particular
attention
to
Cue
Bias
indication
on
one
meter,
simultaneous
with
Cue
Reproduce
levels
indicated
on
the
other.
Refer
to
the
metering
chart
in
Section
II
for
details.
5-3