EasyManua.ls Logo

3M DELTA Series - Mechanical Adjus Men S; Procedure for Delta

3M DELTA Series
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
o
SECTION
in
-
MECHANICAL
ADJUSTMENTS
A.
IMPORTANT
CONSIDERATIONS
The
rugged
mechanics
built
into
Delta
Series
cartridge
machines
are
designed
to
provide
ex
tremely
reliable
and
long-term
operation
with
a
minimum
of
simplified
adjustments.
The
sequence
in
which
mechanical
adjustments
are
completed,
however,
is
important
due
to
the
fact
that
many
of
these
adjustments
are
interrelated.
Therefore,
if
a
complete
check
of
all
mechanical
adjustments
is
required,
start
at
the
beginning
of
this
section
and
follow
the
proper
sequence.
GAUGE,
PRESSURE
ROLLER
PRESSURE
(830-0042-011)
Figure
3-1
Alignment
gauges
to
which
references
are
made
are
available
from
ITC.
The
pressure
roller
pressure
gauge,
830-0042-
011
has
been
designed
exclusively
for
use
in
the
ITC
Delta
Series.
When
utilized
for
either
checking
or
adjusting
pressure
roller
pressure,
a
clear
under
standing
of
its
purpose
will
be
most
helpful
in
mak
ing
an
accurate
and
speedy
set-up.
The
three
primary
width
dimensions
are
shown.
Dimensions
"A"
and
"B"
are
used
to
measure
the
range
of
pressure
roller
pressure.
Dimension
"A"
measures
maximum
roller
pressure.
Dimension
"B"
is
used
to
show
when
pressure
roller
pressure
is
too
low.
The
pressure
of
the
pressure
roller
is
properly
adjusted
when
dimension
"A"
slides
between
the
capstan
shaft
and
pressure
roller
shaft
and
dimen
sion
B"
does
not.
Dimension
"C"
is
a
low-tolerance
dimension,
and
should
never
be
used
to
measure
any
mechan
ical
parameter
in
the
Delta
Series.
Its
prime
function
is
as
a
handle
and
may
be
held
at
this
point
or
at
any
place
along
its
length.
B.
PRESSURE
ROLLER
SHAFT/CAPSTAN
SHAFT
(MOTOR)
POSITION
The
following
adjustments
are
necessary
if
a
motor
or
solenoid
has
been
removed.
The
adjust
ment
should
be
checked
any
time
a
new
pressure
roller
is
installed.
NOTE:
The
pressure
roller
capstan
shaft
locator
gauge
(ITC
Part
#830-0043-001)
and
the
pressure
roller
pressure
gauge
(ITC
Part
#830-0042-011)
are
required
for
the
following
procedure.
Procedure
for
Delta
I
and
Units
1.
Remove
the
pressure
roller
and
place
the
spe
cial
locator
gauge
(830-0043-011)
over
the
pres
sure
roller
shaft
as
illustrated
in
Figure
3-2.
Man
ually
move
the
gauge
up
to
(against)
the
cap
stan
shaft.
Check
to
see
that
the
gauge
surface
lies
flat
against
the
capstan
shaft.
If
not,
loosen
the
motor
mounting
screws,
and
gently
move
the
motor
until
the
gauge
surface
and
the
motor
shaft
are
"flat"
against
each
other.
3-1