EasyManua.ls Logo

3M Dynapro ET 3170 Terminal Series B - Parameters; Table F: Default Values of Setup Parameters

3M Dynapro ET 3170 Terminal Series B
125 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3M Touch Systems Proprietary Information
30
3M Dynapro ET 3170 Terminal User’s Installation Guide
Parameters
Defaults
The first time that power is applied to the terminal, each Setup parameter is set to
its original, factory-programmed default value (see Table F).
Programmable
Parameters that can be programmed by the user using the Setup screen are
described in the following paragraphs. Parameters that can also be programmed
by remote commands from the host computer are identified as “remote
programmable.”
Background (remote programmable)
! Normal video: Light characters against dark background (Default)
! Reverse video: Dark characters against a light background.
Table F: Default values of Setup parameters
Parameter Default Value
Background normal
Foreground Color 37
Background Color 40
Display Activity on
Cursor Type slow-blinking block
NRC off
Address RS-232
Baud Rate 9600
Data Bits 8
Parity Enable off
Parity Sense odd
Stop Bits 1
XON/XOFF on
Local Echo off
Local/Remote remote
New Line off
Auto-Wrap off
H/W Handshake none
Transmit Mode normal

Table of Contents