EasyManuals Logo

3M Dynatel 2250M Series User Manual

3M Dynatel 2250M Series
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
CONFIGURING THE RECEIVER
In the setup mode the units of depth measurement, time, date, and date
format can be set. The receiver can be configured to detect only certain
frequencies and/or specific utility markers. User defined frequencies can be
programmed, language of the receiver can be selected, and Tone frequencies set.
The RS232 com port can be configured for a computer or various types of GPS
devices.
Selecting Depth Units
Menu [6] + Setup [SK] +Units [SK]
Press Units [SK].
The soft key command will toggle between inches (in),
centimeters (cm), and feet/inches (ft-in).
Selecting a Language
Menu [6] + Setup [SK] + Lang [SK]
The soft key command will cycle through all available languages.
Enabling/Disabling Frequencies
Menu [6] + Setup [SK] + More>> [SK] + Locate Freq [SK]
The user can select the frequencies that the receiver will detect. All the
available frequencies are listed in four groups (L to R: Active, Power,
Passive, and Auxiliary). The Auxiliary group also contains the User Defined
Frequencies. (See Creating User Defined Frequencies.)