19
Five depth readings can be saved with the time, date, and relative current
measured.
Save [SK] will place each entry in sequential order in memory (M1 - M5)
until five readings have been stored. The unit will overwrite saved entries
in excess of five, beginning with M1.
Press Clear All [SK] to delete all stored depth information.
The operator may select the memory location to store the depth readings
by pressing Mem Select [SK]. When the preferred location appears on the
screen, press Save [SK]. The screen and memory location will populate with
the current information.
Each memory location can be reviewed by pressing Mem Select [SK].
Press Locate [5] to return to Locate Mode.
Frequencies
Active
Active frequencies are used to trace signals supplied by a 3M
Dynatel
Transmitter 2200 Series (577 Hz, 8 KHz, 33 KHz, or 200 KHz).
Select the frequency that the transmitter is generating.
Press Locate [5]
Press Cable/Pipe [SK]
Press Freq [SK]
Press ACTIVE [SK Toggle] until the desired frequency is displayed in the
soft key command [9] (“Active” 577, 8K, 33K or 200K)
Press Locate [5] to return to Locate mode.