Modes Directional Peak
Directional Null
Special Peak
Frequency Response:
Active 577 Hz
8 KHz
33 KHz
133 KHz (E ver.)
200 KHz (US ver.)
Passive 31.5 KHz (CATV)
9 – 30 KHz (LF)
Power 50 Hz (5th and 9th harmonic)
60 Hz (5th and 9th harmonic)
(100 / 120 Hz) rectified power
Auxiliary 273 Hz
333 Hz
340 Hz
393 Hz
400 Hz
460 Hz
512 Hz
560 Hz
User Defined Frequencies Four
Display LCD
Gain Control Manual and Automatic
Weight w/batteries 4-5 lbs. (model dependent)
Battery Qty. and size 8 AA
Battery life 30 hours average
Depth Accuracy ±2% ±2 in. (5 cm) for
0–60 in. (1.5 m)
±6% ±2 in. (5 cm) for
60–120 in. (1.5–3.0 m)
±10% ±2 in. (5 cm) for
120–180 in. (3.0 m–4.5 m)
Depth Range 0–360 in. (0–914 cm)
Marker depth accuracy +/- 15% +/- 2 inches
Program range XR-iD Markers: 12 in (30 cm)
Read range XR-iD Ball Markers: 60 inch (5 ft)
Receiver Specs 3M
Dynatel
Locators 2250M and 2273M