54
087-0020 REV E
Freedom™ 5000 Model Configuration
Model 50AA -BB - C - D - E - F
AA: Type of Gas
Select from the Master Gas List for gas and range.
BB: Ranges
01- No Sensor 60- 0-150 PPM
05- 0-1 PPM 65- 0-200 PPM
10 - 0-2 PPM 70 - 0-250 PPM
15- 0-3 PPM 75 - 0-300 PPM
20 - 0-5 PPM 80 - 0-500 PPM
25 - 0-10 PPM 85 - 0-1000 PPM
30 - 0-15 PPM 90- 0-1500 PPM
35- 0-20 PPM 1A - 0 to 500 ppb
40- 0-25 PPM 1B- 0-1000 PPB
45- 0-30 PPM 1C- 0-1%
50 - 0-50 PPM 1D- 0-4%
55- 0-100 PPM 1E- 0-5%
1F- 0-10%
1G- 0-25%
C: Sensor Connection/Housing
1- Integral Sensor w/Transmitter
2- Separated Sensor w
/ 3 feet of cable. Longer/shorter cable lengths up to 50 feet max can be specified. Cable is double shielded with
plastic braided external covering. Ideally suited for indoor application.
3- Integral Sensor with transmitter and SST option. SST not available with remote sensor, flowcell, or duct mount configurations
4- REMOTE SE
NSOR MOUNT OPTION FOR RIGID CONDUIT INSTALLATIONS: Conduit not supplied. Separated sensor with 3 feet
of cable. Longer/shorter cable lengths up to 50 feet max can be specified. Scott Safety does not recommend combining “duct mount
adaptor” option with “rigid conduit Installations” as this configuration makes sensor removal from the adaptor difficult.
5- FLEXIBLE
CONDUIT OPTION: Separated sensor with 3 feet of cable and flexible conduit supplied.
Flexible conduit is PVC jacketed metal, sunlight resistant, liquid tight, 3/4” conduit with aluminum fittings supplied.
D: Adapters
1- None
2- Rain Shield
3- Flat Duct
4-Round Duct (6-8 inches typical)
5- Flow Cell
E: SST (Sensor Self-Test Option)
1- None
2- Type A : [Option C3 must also be ordered] Type A
used with Rock Solid BCL3, BF3, Cl2, CLO2, HBr,
HCL, HF, O3, SO2, SiF4, WF6 sensors and
convention Cl2 sensor. SST not available with
remote sensor, flowcell, humishield, or duct mount
configurations
3- Type B: For future use.
F: Transmitter Mounting Adaptor
1- None
2- Wall/Surface
3- “L” bracket used for mounting on horizontal surfaces
Freedom 5000 Universal Analog Toxic Gas Detector
Instruction Manual