Versao
Powered Air Purifying Respirator (PAPR) Assembly
User Instructions for 3M™ Versao™ Powered Air Purifying Respirator TR-300 Belt Mounted Assemblies.
Ensemble respirateur d’épuration d’air propulsé Versao™
Directives d’utilisation pour les ensembles respirateurs d’épuration d’air propulsé montés à la ceintureTR-300
Versao™ 3M™
Respirador Puricador de Aire Forzado (PAPR)
Instrucciones para Respirador Puricador de Aire Forzado 3M™ Versao™ TR-300, montado en cinturón
Instalação do Respirador Puricador de Ar Motorizado (PAPR)
Manual de Instruções para o Conjunto Motorizado PAPR da Série TR-300 Versao™ da 3M™
IMPORTANT: Before use, the wearer must read and understand these User Instructions. Keep these User Instructions
for reference.
IMPORTANT : Avant de se servir du produit, l’utilisateur doit lire et comprendre les présentes directives d’utilisation.
Conserver ces directives d’utilisation à titre de référence.
IMPORTANTE: Antes de usar el producto, el usuario debe leer y entender estas Instrucciones. Conserve estas
Instrucciones para referencia futura.
IMPORTANTE: Antes de usar, o usuário deve ler e compreender este Manual de Instruções. Guarde este Manual de
Instruções para futura referência.
W WARNING
This product is part of a system that helps protect against certain airborne contaminants. Misuse may
result in sickness or death. For proper use, see supervisor, User Instructions or call 3M in U.S.A.,
1-800-243-4630. In Canada, call Technical Service at 1-800-267-4414.
W MISE EN GARDE
Ce produit fait partie d’un système qui protège contre certains contaminants en suspension dans
l’air. Une mauvaise utilisation peut provoquer des problèmes de santé ou la mort. Pour tout
renseignement sur l’utilisation adéquate de ce produit, consulter son superviseur, lire les directives
d’utilisation ou communiquer, au Canada, avec le Service technique de 3M au 1 800 267-4414.
W ADVERTENCIA
Este producto es parte de un sistema que ayuda a proteger contra ciertos contaminantes suspendidos
en el aire. El mal uso puede ocasionar enfermedad o incluso la muerte. Para su uso adecuado
consulte a su supervisor, lea las Instrucciones, o llame a 3M en EUA al 1-800-243-4630. En Canadá
llame al Servicio Técnico al 1-800-267-4414. En México llame al 01-800-712-0646. O contacte a 3M
en su país.
W ADVERTÊNCIA
Este produto faz parte de um sistema que ajuda a proteger contra determinados contaminantes
suspensos no ar. O uso incorreto do mesmo pode causar enfermidade ou morte. Para seu uso
correto, converse com o supervisor, consulte o Manual de Instruções, ou ligue para a 3M no Disque
Segurança 0800-0550705.
TR-300
Series/Série/Serie/Série
sales@bestmaterials.com | http://www.bestmaterials.com | 1-800-474-7570
DISTRIBUTED BY
®

Questions and Answers

  • D
    Daniel JohnsonAug 1, 2025
    What to do if my 3M Respiratory Product has a low airflow alarm?
    • K
      kevin90Aug 1, 2025
      If your 3M Respiratory Product triggers a low airflow alarm, first check the breathing tube for any blockages and remove them. Also, ensure the air inlet isn't covered by any obstruction. Finally, if the filter is clogged with particles, replace the HE filter and prefilter or spark arrestor/prefilter.
  • J
    Jeffrey PerezAug 5, 2025
    Why does my 3M Versaflo TR-300 Respiratory Product battery die so fast?
    • S
      Scott ChristensenAug 5, 2025
      If your 3M Respiratory Product's battery isn't lasting as long as it should, make sure it's fully charged. A HE filter loaded with particles can cause the motor to work harder, so check the low flow indicator and replace the HE filter and prefilter or clean the spark arrestor. Finally, the battery pack may be reaching the end of its service life and need replacement.
  • J
    jenniferstricklandAug 9, 2025
    What to do if the battery indicator is flashing on my 3M Versaflo TR-300 Respiratory Product?
    • U
      uclarkAug 9, 2025
      If the bottom bar of the battery pack indicator is flashing and the battery alarm is sounding on your 3M Respiratory Product, try these steps: recharge the battery pack, remove and reinstall the battery pack to ensure it's properly connected. If that doesn't work, the battery pack might be past its service life and needs replacing with a new, fully charged TR-300 battery pack. Also, if the battery pack temperature is too hot (above 140°F or 60°C), bring it to a cooler environment to cool down.
  • J
    James BowmanAug 13, 2025
    How to fix all LEDs flashing and alarm on 3M Respiratory Product?
    • C
      Carol VelezAug 13, 2025
      If all the LEDs are flashing and the alarm is sounding on your 3M Respiratory Product, it may indicate a system software malfunction. To clear the alarm, power down the motor/blower unit and remove the battery pack. Let it sit for a few minutes before reconnecting the battery pack and turning the unit back on. If it doesn't reset, contact 3M Technical Service.
  • C
    Charles GriffithAug 18, 2025
    Why is there no airflow from my 3M Versaflo TR-300 and no alarms?
    • K
      Karen GrantAug 18, 2025
      If there is no airflow and no alarms on your 3M Respiratory Product, check that the battery pack contact is not bent or broken. Also, fully charge the battery pack. If problems persist, contact 3M Technical Service.
  • U
    uwagnerAug 22, 2025
    Why is the motor running faster than normal on my 3M Versaflo TR-300 Respiratory Product?
    • S
      Savannah AndersonAug 22, 2025
      If the motor on your 3M Respiratory Product is running faster than normal, it might be because the HE filter is loaded with particles. Check the low flow indicator and replace the HE filter and prefilter, and clean the spark arrestor. Also, let the unit run for 2 minutes so it can automatically adjust to the new filter or changes to the filter configuration.
  • C
    codyaguilarAug 27, 2025
    What to do if low airflow is indicated but there are no alarms on my 3M Versaflo TR-300 Respiratory Product?
    • C
      Christopher MooreAug 27, 2025
      If the flow meter indicates low airflow but there are no alarms on your 3M Respiratory Product, ensure the flow indicator is held in a vertical position during inspection. If problems persist, contact 3M Technical Service.

Summary

Foreword and System Information

Contact Information

Provides contact details for technical service and websites for further inquiries.

System Description

Details the TR-300 PAPR assembly, its components, and basic function.

List of Warnings

Lists important safety warnings to be aware of before using the product.

Limitations of Use

Outlines conditions under which the respirator system should not be used.

Respirator Program Management and NIOSH Approval

OSHA Standard Sections

Lists key sections of the OSHA Respiratory Protection standard for compliance.

NIOSH Approval Details

States the TR-300 is part of a NIOSH-approved respiratory system.

NIOSH Cautions and Limitations

Lists specific cautions and limitations mandated by NIOSH for respirator use.

Operating Instructions

Unpacking

Instructions for checking package contents for shipping damage and completeness.

Assembly - Battery Pack

Details on charging, installing, and removing the battery pack.

Assembly - Filters

Procedures for installing and removing the HE filter, prefilter, and spark arrestor.

Assembly - Belt, Backpack, Suspenders

Instructions for attaching optional belts, back packs, and suspenders.

Assembly - Breathing Tube

Guides on how to connect the breathing tube to the motor/blower.

Head Gear Attachment

Refers to headgear user instructions for attachment and donning procedures.

Powering On and Off

How to turn the TR-300 motor/blower on and off, including self-diagnostic.

Airflow Check Procedure

Procedures for checking the system's airflow using the indicator and testing alarms.

Inspection Procedure

General Safety Warnings

Essential safety precautions and warnings to follow during inspection.

Pre-Use Inspection Steps

Step-by-step guide for performing a thorough inspection before using the respirator.

Entering and Exiting Contaminated Areas

Conditions Requiring Immediate Exit

Lists critical conditions requiring immediate exit from the contaminated area.

Safe Exit and Decontamination

Guidelines for safely exiting contaminated areas and procedures for turning off/removing the respirator.

Cleaning and Storage

Cleaning Procedures

Instructions for cleaning the motor/blower, breathing tube, and HE filter.

Storage Recommendations

Guidelines for storing the motor blower, battery packs, and filters.

Specifications and Troubleshooting

Technical Specifications

Lists technical details including airflow, operating temperature, altitude, and shelf life.

Battery Pack and Charger Specs

Details on battery chemistry, run time, recharge time, and charger LED indicators.

Motor;blower Alarms

Explains the low airflow and low battery pack voltage alarms.

Filter Service Life

Guidance on when to change the HE filter, prefilter, and spark arrestor.

Troubleshooting Guide

Identifies possible faults, their causes, and suggested solutions for common issues.

Related Documents and Warranty

Supporting Documents

Lists related user instructions, technical specifications, and guides for the TR-300 system.

Warranty Information

Details 3M's warranty coverage, limitations, and exclusions for PAPR systems.

3M Versaflo TR-300 Series Specifications

General IconGeneral
Product TypePowered Air Purifying Respirator (PAPR)
Battery TypeLithium-ion
Product SeriesTR-300 Series
Operating Temperature-10°C to 55°C
Storage Temperature-40°F to 140°F (-40°C to 60°C)
Battery Life6-12 hours
Airflow185 L/min