TR-300/TR-300-SG* Powered Air Purifying
Respirator (PAPR) Assembly
User Instructions for 3M™ Versafl o™ TR-300 and 3M™ Speedglas™ TR-300-SG*
Series Belt Mounted PAPR Assemblies.
*Catalog number only. NIOSH approved and referred to as 3M™ TR-300 PAPR.
Ensembles respirateurs d’épuration d’air propulsé
TR-300 et TR-300-SG*
Directives d’utilisation pour les ensembles respirateurs d’épuration d’air propulsé
montés à la ceinture Versafl o™ 3M™ de série TR-300 et Speedglas™ 3M™ de
série TR-300-SG*
* Numéro de référence seulement. Homologué par le NIOSH sous la désignation suivante : respirateur
d’épuration d’air propulsé TR-300 3M
.
Ensamble de Respirador Purifi cador de Aire
Forzado (PAPR) TR-300/TR-300-SG*
Instrucciones para Ensambles PAPR 3M™ Versafl o™ TR-300 y 3M™ Speedglas™
TR-300-SG* montados en cinturón
*Sólo es un número de catálogo. Aprobado por el Instituto Nacional de Seguridad y Salud Ocupacional
(NIOSH por sus siglas en inglés) y referido como PAPR 3M™ TR-300.
Instalação do Respirador Purifi cador de Ar
Motorizado (PAPR) das Séries TR-300/TR-300-SG*
Manual de Instruções para o Conjunto Motorizado PAPR da Série TR-300 Versafl o™
da 3M™ e Série TR-300-SG* Speedglas™ da 3M™
* Apenas numeração do catálogo. Aprovado e mencionado pela NIOSH como PAPR TR-300 da 3M™
IMPORTANT: Before use, the wearer must read and understand these User Instructions. Keep these
User Instructions for reference.
IMPORTANT : Avant de se servir du produit, l’utilisateur doit lire et comprendre les présentes
directives d’utilisation. Conserver ces directives d’utilisation à titre de référence.
IMPORTANTE: Antes de usar el producto, el usuario debe leer y entender estas Instrucciones.
Conserve estas Instrucciones para referencia futura.
IMPORTANTE: Antes de usar, o usuário deve ler e compreender este Manual de Instruções. Guarde
este Manual de Instruções para futura referência.

Table of Contents

Other manuals for 3M Versaflo TR-300-SG

Questions and Answers

  • N
    Nathan VangAug 15, 2025
    How to fix a low airflow alarm on a 3M Versaflo TR-300-SG Respiratory Product?
    • B
      Bryan Clark DVMAug 15, 2025
      If your 3M Respiratory Product has a low air flow alarm (audible and/or LED flashing), it could be due to a blocked breathing tube. Check the breathing tube and remove any blockage or obstruction. Another possible cause is a covered air inlet. Inspect the air filter and remove any obstruction. Finally, the filter might be fully loaded with particles. In this case, change the HE filter and prefilter or spark arrestor/prefilter.
  • M
    Melissa WilsonAug 18, 2025
    What to do if I smell contaminants using 3M Respiratory Product?
    • R
      Ryan JohnsonAug 18, 2025
      If you detect an odor or taste of contaminants or feel eye or throat irritation while using your 3M Respiratory Product, it may be due to using the incorrect respirator for your specific application and/or environment. In this case, no other solution is available.
  • M
    morenotanyaAug 22, 2025
    Why does the battery die so fast on my 3M Respiratory Product?
    • L
      Laura BrownAug 22, 2025
      If your 3M Respiratory Product's battery pack charge lasts less than expected, ensure the battery pack is fully charged. Also, a HE filter loaded with particles can make the motor work harder, so check the low flow indicator and replace the HE filter & prefilter or clean the spark arrestor. The battery pack might also be nearing the end of its service life, so consider replacing it.
  • M
    Mark KellyAug 25, 2025
    How to reset alarm when all LEDs are flashing on 3M Respiratory Product?
    • C
      Candice PorterAug 26, 2025
      If all LEDs are flashing and an alarm is sounding on your 3M Respiratory Product, it indicates a system software malfunction. To clear the alarm, power down the motor/blower unit and remove the battery pack. Let the unit sit for several minutes before reconnecting the battery pack and turning the unit back on. If the unit does not reset, no other solution is available.
  • C
    cameronwadeAug 28, 2025
    Why is my 3M Versaflo TR-300-SG Respiratory Product motor running faster than normal?
    • O
      orozcojohnAug 28, 2025
      If the motor of your 3M Respiratory Product runs 'faster than normal', check the low flow indicator. Replace the HE filter & prefilter and clean the spark arrestor, as the HE filter might be loaded with particles. Then, let the unit run for 2 minutes so it can automatically adjust to the new filter or changes to the filter configuration.
  • L
    linryanSep 1, 2025
    What to do if the bottom bar of battery pack indicator flashes and battery alarm sounds in 3M Versaflo TR-300-SG Respiratory Product?
    • N
      Nathan FischerSep 1, 2025
      If the bottom bar of the battery pack indicator flashes and the battery alarm sounds, it could be due to several reasons. It may be caused by low battery voltage, in which case you should recharge the battery pack. Another cause could be that the battery pack is not properly installed, so try removing and reinstalling it. If the battery pack is past its service life, install a new, fully-charged battery pack. Finally, if the battery pack temperature is too hot (greater than 140ºF or 60ºC), bring it to a cooler environment and allow it to cool down.
  • B
    Billy HortonSep 4, 2025
    What to do if my 3M Versaflo TR-300-SG Respiratory Product battery pack’s charge lasts less than expected?
    • T
      timothy71Sep 4, 2025
      If your battery pack's charge is not lasting as long as expected, there are a few things to consider. First, ensure that the battery pack is fully charged. Also, a HE filter loaded with particles can make the motor work harder, so check the low flow indicator and replace the HE filter and prefilter or clean the spark arrestor. Finally, the battery pack may be reaching the end of its service life, which means it's time to replace it.
  • N
    Natalie MontoyaSep 7, 2025
    Why does my 3M Versaflo TR-300-SG have a low air flow alarm?
    • J
      Jeffrey WilliamsSep 7, 2025
      A low air flow alarm (audible and/or LED flashing) can occur for several reasons. The breathing tube may be blocked, so check and remove any blockage or obstruction. The air inlet could be covered, so check the air filter and remove any obstruction. Also, the filter may be fully loaded with particles, in which case you should change the HE filter and prefilter or spark arrestor/prefilter.
  • G
    Glenda WilliamsSep 12, 2025
    Why is the motor running faster than normal in my 3M Versaflo TR-300-SG?
    • L
      Linda JohnsonSep 12, 2025
      If the motor runs faster than normal, it could be because the HE filter is loaded with particles. In this case, check the low flow indicator and replace the HE filter and prefilter, and clean the spark arrestor. Also let the unit run for 2 minutes so it can automatically adjust to the new filter or changes to the filter configuration.