EasyManua.ls Logo

3MINDWAVE APEX REBELS MOTION - Air Compressor Troubleshooting

3MINDWAVE APEX REBELS MOTION
169 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 115
52
Gas Canister
1
53
Knob Cover
1
54
Knob
1
55
Hexagon Socket Cheese Head Screws
4
56
Drain Valve
1
57
M6 Nut
4
58
Gasket
4
59
Boss Machine Foot Mats
4
60
Foot Screws
4
61
Power Cable
1
6.4.2 Air Compressor Troubleshooting
No.
Fault Phenomenon
Possible Cause
Methods of Troubleshooting
1
Air compressor does not work;
No motor sound.
1) Socket has no power.
Power On.
2) Overcurrent protector or pressure
controller is not connected.
Check if the wiring of the
overcurrent protector and the
pressure controller is connected.
2
Air compressor stops when
setting is not set to the
maximum pressure.
1) Pressure switch setting is in low.
Adjust the Pressure switch value
to the required value.
2) Overvoltage or under voltage,
overcurrent protector is out of work.
Check voltage and replace
overcurrent protector.
3
Air compressor cannot
normally pneumatic, motor will
stop after turning;
and Has
motor sound, but the sound
disappears after 10~30
seconds.
1) Voltage is too low.
Increase the voltage regulator
and start the air compressor
again when the voltage is back to
normal.
2) The gas in the exhaust pipe is not
emptied when pneumatic;
Poor plug contact or intermediate
power failure occurs more often.
Pull out the plug and replace the
socket to ensure good contact.
Turn off the air pressure switch
to remove the gas in the exhaust
pipe, and then turn the switch
back on (time > 5 seconds)
3) Compressor capacitor is damaged or
capacity is reduced.
Replace the capacitor.
4) Air Compressor is totally out of
work.
Contact the manufacturer.
4
The compressor runs
continuously, but when the
pressure does not reach the
stop pressure or the exhaust
ball valve is closed, the time
when the stop pressure is
reached increases.
1) Air leakage of air compressor and
piping system.
Check for leaks at each joint
(soapy water can be used).
2) Compressor head failure is out of
work.
Open the cylinder cover to check
whether the valve has carbon
deposit and whether the valve is
warped or leather is worn.
Contact the manufacturer.