EasyManuals Logo

A.O. Smith BFC Cyclone User Manual

A.O. Smith BFC Cyclone
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #103 background imageLoading...
Page #103 background image
Size Description Unit BFC 80 BFC 100 BFC 120
A Overall height mm 2060 2060 2060
C Position on pallet mm 530 530 530
D Appliance diameter mm 850 850 850
E Depth mm 1000 1000 1000
F Width mm 900 900 900
G Diameter of flue gas
discharge
mm 130/200 130/200 130/200
H Height of flue gas
outlet/air supply
mm 1995 1995 1995
Hx x position flue gas
outlet
mm 310 310 310
Hy x position flue gas
outlet
mm 440 440 440
K Height of gas
connection
mm 1855 1855 1855
M Height of cold water
supply
mm 225 225 225
N Height of hot water
outlet
mm 2060 2060 2060
Ny y position of hot water
outlet
mm 205 205 205
P Height of cleaning
opening
mm 290 290 290
R Height of drain valve
connection
mm 225 225 225
S Height of T&P valve
connection
mm 1425 1425 1425
W Height of condensation
drain
mm 240 240 240
1 Cold water supply
connection (external)
-
R 1
1
/
2
R 1
1
/
2
R 1
1
/
2
2 Hot water outlet
(male)
-
R 1
1
/
2
R 1
1
/
2
R 1
1
/
2
3 Gas control valve
connection (external)
-
R
3
/
4
" R
3
/
4
" R
3
/
4
"
4 Drain valve connection
(internal)
-
3
/
4
"
3
/
4
"
3
/
4
"
5 T&P valve connection
(female)
- 1"-11.5 NPT 1"-11.5 NPT 1"-11.5 NPT
6 Cleaning/inspection
opening
mm 95 x 70 95 x 70 95 x 70
7 Condensation drainage
connection (female)
- Ø 40 Ø 40 Ø 40
0311704_BFC_28-120_III_ENEN_V2.4, 2022-10-17 103

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the A.O. Smith BFC Cyclone and is the answer not in the manual?

A.O. Smith BFC Cyclone Specifications

General IconGeneral
BrandA.O. Smith
ModelBFC Cyclone
CategoryWater Heater
LanguageEnglish

Related product manuals