12.3 Gas details
Description Unit BFC 28 BFC 30 BFC 50 BFC 60
Gas category 2H: G20
Diameter of the venturi
restrictor
mm - - - -
Nominal Load (gross) kW 32.2 33.3 52.2 63.3
Nominal output kW 31.0 32.7 50.3 60.4
Supply pressure mbar 20 20 20 20
CO
2
(full load) vol% 9.0 ± 1.0 9.0 ± 1.0 9.0 ± 1.0 9.0 ± 1.0
O
2
(full load) vol% 4.8 ± 1.8 4.8 ± 1.8 4.8 ± 1.8 4.8 ± 1.8
Gas consumption
(1)
m
3
/h
3.1 3.2 5.0 6.0
NO
x
-emission mg/kWh GCV 24 32 36 37
Mass flow rate flue gases
(minimal load)
kg/h 24.3 24.3 24.3 24.3
Mass flow rate flue gases
(nominal load)
kg/h 52.2 54.0 84.6 102.6
Flue gas temperature
(nominal load)
ºC 44 54 63 68
Gas category 3P: G31
Diameter of the venturi
restrictor
mm 6.00 6.00 6.00 6.00
Nominal Load (gross) kW 31.5 32.6 51.1 62.0
Nominal output kW 31.0 32.7 50.3 60.4
Supply pressure mbar 37 / 50 37 / 50 37 / 50 37 / 50
Gas control valve pressure mbar 12.0 ± 2.0 12.0 ± 2.0 12.0 ± 2.0 12.0 ± 2.0
CO
2
(full load) vol% 10.0 ± 1.0 10.0 ± 1.0 10.0 ± 1.0 10.0 ± 1.0
O
2
(full load) vol% 5.7 ± 1.8 5.7 ± 1.8 5.7 ± 1.8 5.7 ± 1.8
Gas consumption kh/h 2.3 2.3 3.7 4.4
NO
x
-emission mg/kWh GCV 31 39 42 45
Mass flow rate flue gases
(minimal load)
kg/h 24.8 24.8 24.8 24.8
Mass flow rate flue gases
(nominal load)
kg/h 53.3 55.2 86.4 104.8
Flue gas temperature
(nominal load)
ºC 44 54 63 68
1 - Based on 1013.25 mbar and 15°C.
0311704_BFC_28-120_III_ENEN_V2.4, 2022-10-17 105

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the A.O. Smith BFC Cyclone and is the answer not in the manual?

A.O. Smith BFC Cyclone Specifications

General IconGeneral
BrandA.O. Smith
ModelBFC Cyclone
CategoryWater Heater
LanguageEnglish

Related product manuals