EasyManuals Logo

A.O. Smith BFC Cyclone User Manual

A.O. Smith BFC Cyclone
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #110 background imageLoading...
Page #110 background image
Cable colors: Components: Terminal block connections:
1 Brown A Control J2 Power connection for controller
2 Blue B Flame probe J19 Extra error signal connection
3 Yelow/Green C Hot surface igniter J20 Gas control valve connection
4 Black D Gas control valve J21 Program-controlled pump
connection
5 White E Burner earth connection
6 Grey/Beige F External ON mode switch J40 Fan connection
7 Green G Program-controlled pump
(max. 100 W)
J36 Controller display connection
JP2 Flame probe and hot surface
igniter connection
Terminal block connections: H Extra error signal connection
A
Earth J Isolating transformer JP3 Temperature sensor
T
2
connection
N Neutral K Double-pole isolator
L Live input of controller L Controller O/I switch JP4 Dummy connection
L
1
Phase input of isolating
transformer (primary side)
M Display JP5 Temperature sensor
T
1
connection
N Fan
L
2
Phase input of isolating
transformer (secondary side)
O Temperature sensor
(T
2
- bottom of tank)
JP6 Selection resistor and pressure
switch connection
L
3
Phase input of
program-controlled pump
P Dummy JP8 Extra ON mode switch connection
Q Temperature sensor
(T
1
- top of tank)
R Selection resistor F1 Fuse (T 3.15 A - 250 V)
S Push button F3 Fuse (T 3.15 A - 250 V)
T Electrical anodes
U Signaling for electrical anodes
V Potentiostat
110 Installation, Maintenance and Service part

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the A.O. Smith BFC Cyclone and is the answer not in the manual?

A.O. Smith BFC Cyclone Specifications

General IconGeneral
BrandA.O. Smith
ModelBFC Cyclone
CategoryWater Heater
LanguageEnglish

Related product manuals