Description Unit Value
Maximum mains pressure of
cold water supply (vented)
kPa (bar) 800 (8)
Maximum mains pressure of
cold water supply (unvented)
kPa (bar) 550 (5.5)
Maximum mains pressure of
the protected cold supply
setup
kPa (bar) 500 (5)
T&P overflow pressure kPa (bar) 1000 (10)
T&P overflow temperature °C 97
Description Unit BFC 28 BFC 30 BFC 50 BFC 60
Load profile - XXL XXL XXL XXL
Energy Efficiency Class
(Energy Label)
- A A A A
Energy Efficiency % 91 91 91 90
Daily Electricity Consumption kWh 0.207 0.210 0.211 0.212
Daily Fuel Consumption kWh GCV 26.501 26.552 26.562 26.632
Mixed Water 40°C (V40) ltr. 1255
¥ ¥ ¥
Additional Load Profile - - - 3XL 3XL
Energy Efficiency % - - 89 89
Daily Electricity Consumption kWh - - 0.251 0.252
Daily Fuel Consumption kWh GCV - - 52.051 52.162
Mixed Water 40°C (V40) ltr. - - 559 601
98 Installation, Maintenance and Service part