9
INSULATION BLANKETS
Do not obstruct water heater air intake
with insulating blanket.
Gas and carbon monoxide detectors
are available.
Install water heater in accordance with
the instruction manual.
Breathing carbon monoxide can cause brain damage or
death. Always read and understand instruction manual.
Breathing Hazard - Carbon Monoxide Gas
Insulation blankets are available to the general public for
external use on gas water heaters but are not necessary
with these products. The purpose of an insulation blanket is
to reduce the standby heat loss encountered with storage
tankheaters.Thewaterheaterscoveredbythismanualmeet
or exceed the Energy Policy Act standards with respect to
insulation and standby heat loss requirements, making an
insulationblanketunnecessary.
Shouldyouchoosetoapplyaninsulationblankettothisheater,
you should follow these instructions. See the Installation
Considerations section of this manual for identification
of components mentioned below. Failure to follow these
instructions can restrict the air flow required for proper
combustion,potentiallyresultinginfire,asphyxiation,serious
personalinjuryordeath.
• DO NOTapplyinsulationtothetopofthewaterheater,as
thiswillinterferewithsafeoperationofthedrafthood.
• DO NOTcoverthethermostatortheTemperature-
PressureReliefValve.
• DO NOTallowtheinsulationtocomewithin2inches(5
cm)ofthefloortopreventblockageofcombustionairflow
to the burner.
• DO NOTcovertheinstructionmanual.Keepitontheside
ofthewaterheaterornearbyforfuturereference.
• DOobtainnewwarningandinstructionlabelsfromthe
manufacturerforplacementontheblanketdirectlyover
theexistinglabels.
• DOinspecttheinsulationblanketfrequentlytomake
certainitdoesnotsag,therebyobstructingthe
combustionairflow.
HARD WATER
Wherehardwaterconditionsexist,watersof teningorthethreshold
type of water treatment is recommended. This will protect the
dishwashers,coffeeurns,waterheaters,waterpipingandother
equipment. See the Maintenance Section in this manual for
sedimentandlimescaleremovalprocedures.
CIRCULATION PUMPS
Acirculatingpumpisusedwhenasystemrequiresacirculating
loop or there is a storage tank used in conjunction with the
water heater. See Water Piping Diagrams in this manual for
installationlocationofcirculatingpumps.
SeetheCirculationPumpWiringDiagramsbelowforelectrical
hookup information. Install in accordance with the current
edition of the National Electrical Code, NFPA 70 or the
CanadianElectricalCode,CSAC22.1.
Allbronzeorstainlesssteelcirculatingpumpsarerecommended
forusedwithcommercialwaterheaters.
Somecirculatingpumpsaremanufacturedwithsealedbearings
anddonotrequirefurtherlubrication.Somecirculatingpumps
must beperiodically oiled. Refertothe pumpmanufacturer’s
instructionsforlubricationrequirements.
CIRCULATING PUMP WIRING DIAGRAM
STORAGE TANK OR BUILDING RECIRCULATION
FIELD SUPPLIED TEMPERATURE CONTROL
INSTALLED IN THE STORAGE TANK
OR CIRCULATING LOOP RETURN LINE
CIRC
PUMP
MOTOR
L1 HOT
L2 NEUTRAL
120 VAC
POWER
NOTE: USE SEPARATE 120 VAC POWER
SUPPLY FOR PUMP CIRCUIT. DO NOT
SHARE POWER WITH WATER HEATER AS THIS
MAY CAUSE ELECTRICAL LINE NOISE AND
LEAD TO ERRATIC CONTROL SYSTEM
OPERATION.
FIGURE 4.
CIRCULATING PUMP WIRING DIAGRAM
DISHWASHER LOOP WITH TOGGLE SWITCH
FIELD SUPPLIED TEMPERATURE
CONTROL INSTALLED IN THE
CIRCULATING LOOP RETURN LINE
DISHWASHER
TOGGLE
SWITCH
CIRC
PUMP
MOTOR
L1 HOT
L2 NEUTRAL
120 VAC
POWER
NOTE: USE SEPARATE 120 VAC POWER
SUPPLY FOR PUMP CIRCUIT. DO NOT
SHARE POWER WITH WATER HEATER AS
THIS MAY CAUSE ELECTRICAL LINE NOISE
AND LEAD TO ERRATIC CONTROL SYSTEM
OPERATION.