110 Indoor / 110 Outdoor Service Manual
Ver. 1.01
25
10-9. Flow sensor
Unit Part # #402 AOS Part # 319143-167
Checkpoint H2
Function
Detects and measures water flow rate using a spinning impeller and
magnetic pick-up.
Failure events
Unable to detect or measure any water flow rate.
Effects on the Water
heater if flow sensor fails
Ignition sequence does not start (Water heater will not initiate any
operation)
Error codes when flow
N/A
Diagnostic
1. Visual inspection: connection/breakage of wires and/or debris on impeller.
2. Check voltages: proper range of values shown below.
Color/Number of wires
Red - Black 4.0 to 5.5 VDC (Input)
White(85) -Black
1.0 to 4.0 VDC (pulse)
1,080 pulse/min (more than 18 Hz)
The flow sensor is assembled with the flow adjustment valve.
IN
OUT
Flow
adjustment
valve
Flowsensor
Flow
adjustment
valve
Flowsensor
OUT
IN
>P PE- GF <
1-7/8" (47mm)
3-3/8" (84.4mm)
2-5/8" (67.5mm)
Flow sensor
OUTPUT
VCC
GND
22
11
3
White
Black
Red
No.1
No.3
No.2
Flow sensor