1-142 ACH550-UH User’s Manual
Parameters
3503 ALARM LIMIT -10...200 C / 1 110 C /
0...5000 ohm / 1500 ohm /
0…1 0
Defines the alarm limit for motor temperature measurement.
At motor temperatures above this limit, the drive displays an alarm (2010,
MOTOR TEMP)
For thermistors or PTC connected to a digital input:
0 – de-activated
1 – activated
3504 FAULT LIMIT -10...200 C / 1 130 C /
0...5000 ohm / 4000 ohm /
0…1 0
Defines the fault limit for motor temperature measurement.
At motor temperatures above this limit, the drive displays a fault (9,
MOT OVERTEMP) and stops the drive.
For thermistors or PTC connected to a digital input:
0 – de-activated
1 – activated
Group 35: Motor Temp Meas
Code Description Range Resolution Default S