EasyManua.ls Logo

ABB ACH550-VCR - Page 223

ABB ACH550-VCR
642 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ACH550-UH User’s Manual 1-219
Embedded fieldbus
{23} LDI RUN.STOP ACT STOP - 1 0 RUN STOP
{24} LDO RUN.STOP CMD STOP - 1 0 RUN STOP
{25} LDI EXT1.2 ACT EXT1 - 1 0 EXT2 EXT1
{26} LDO EXT1.2 CMD EXT1 - 1 0 EXT2 EXT1
{27} LDI DRIVE READY NOTRDY - 1 0 READY NOTRDY
{28} LDI AT SETPOINT NO - 1 0 YES NO
{29} LDO DAY.NIGHT DAY - 1 0 NIGHT DAY
30 LAO CURRENT LIM 0 A 0.1 0 - -
31 LAO ACCEL TIME 1 300 sec 0.1 0 - -
32 LAO DECEL TIME 1 300 sec 0.1 0 - -
{33} LDI HANDAUTO
ACT
AUTO - 1 0 HAND AUTO
{34} LDI ENA.DIS ACT DISABL - 1 0 ENABLE DISABL
{35} LDO ENA.DIS CMD DISABL - 1 0 ENABLE DISABL
{36} LDI FLN LOC ACT AUTO - 1 0 FLN AUTO
{37} LDI FLN CTL SRC NO - 1 0 YES NO
{38} LDI FLN REF1 SRC NO - 1 0 YES NO
{39} LDI FLN REF2 SRC NO - 1 0 YES NO
{40} LDO RO 1
COMMAND
OFF - 1 0 ON OFF
{41} LDO RO 2
COMMAND
OFF - 1 0 ON OFF
{42} LDO RO 3
COMMAND
OFF - 1 0 ON OFF
{43} LDO RO 4
COMMAND
OFF - 1 0 ON OFF
{44} LDO RO 5
COMMAND
OFF - 1 0 ON OFF
{45} LDO RO 6
COMMAND
OFF - 1 0 ON OFF
{46} LAO AO 1
COMMAND
PCT PCT 0.1 0 - -
{47} LAO AO 2
COMMAND
PCT PCT 0.1 0 - -
48 LDO RST RUN TIME NO - 1 0 RESET NO
49 LDO RESET KWH NO - 1 0 RESET NO
50 LAO PRC PID GAIN 10 PCT 0.1 0 - -
51 LAO PRC PID ITIM 600 SEC 0.1 0 - -
52 LAO PRC PID DTIM 0 SEC 0.1 0 - -
53 LAO PRC PID DFIL 10 SEC 0.1 0 - -
FLN Point Database
Point
Subpoint Name
Factory
Default
Engr.
Units
Slope Intercept
On Text Off Text
# Type (SI Units)

Table of Contents

Other manuals for ABB ACH550-VCR