ACH550-UH User’s Manual 1-321
Technical data
Mounting dimensions
R1…R6 mounting dimensions
* Center to center dimension.
UL type 1 and UL type 12 – Dimensions for each Frame Size
Ref.
R1 R2 R3 R4 R5 R6
mm
in mm in mm in mm in mm in mm in
W1* 98.0 3.9 98.0 3.9 160 6.3 160 6.3 238 9.4 263 10.4
W2* -- -- -- -- 98.0 3.9 98.0 3.9 -- -- -- --
H1* 318
12.5 418 16.4 473 18.6 578 22.8 588 23.2 675 26.6
a 5.5 0.2 5.5 0.2 6.5 0.25 6.5 0.25 6.5 0.25 9.0 0.35
b 10.0 0.4 10.0 0.4 13.0 0.5 13.0 0.5 14.0 0.55 14.0 0.55
c 5.5
0.2 5.5 0.2 8.0 0.3 8.0 0.3 8.5 0.3 8.5 0.3
d 5.5 0.2 5.5 0.2 6.5 0.25 6.5 025 6.5 0.25 9.0 0.35
Mounting Hardware
M5
#10 M5 #10 M5 #10 M5 #10 M6 1/4 M8 5/16
X0032
b
H1
See Detail A
a
W1
See Detail B
W2
c
d
Detail B
Detail A