5REPLACEMENT INSTRUCTIONS | ACH580-01 BXR UL TYPE 1 & 12, R1/R2
Step Instruction
Diagram
10
Using a T20 bit, loosen and remove two (2) M4x8 screws. Remove
conduit assembly.
Recycle the conduit assembly and hardware.
11
CAUTION! Use two people to install the drive.
Slide the drive mounting holes over the four (4) screws and slide
drive in place.
Torque all four (4) mounting screws to 27 in-lb (3 Nm).