82 Installation of the ASTO board (Safe torque off, +Q967)
WARNING! The supply voltage for the ASTO-11C board is 24 V DC. If the
board is supplied with 230 V AC, the board is damaged and it needs to be
replaced.
The following figure shows how the external ASTO board is connected the drive. The
cable (length 3 m [10 ft]) is delivered with the ASTO board.
See
page
70
for the location of terminal X41 of the drive.
page 84 for the circuit diagram.
page 160 for the dimensions of the ASTO-11C board.
page 125
for the technical data of the ASTO-11C board.