18 ACS880-01/04 +C132 marine type-approved drives
Definitions – ACS880-01
027A-7 R3 26 46 26 18.5 25 22 15 20
07A3-7 R5 8.6 12.2 8.6 5.5 7.5 5.8 3.0 4.0
09A8-7 R5 10 18 10 7.5 10 8.6 4.0 5.0
14A2-7 R5 16 22 16 11 15 10 5.5 8
018A-7 R5 21 29 21 15 20 16 11 15
022A-7 R5 26 44 26 18.5 25 21 15 20
026A-7 R5 30 54 30 22 30 26 18.5 25
035A-7 R5 39 64 39 30 40 30 22 30
042A-7 R5 49 70 49 37 50 39 30 40
049A-7 R5 49 71 49 37 50 39 30 40
061A-7 R6 59 104 59 45 60 49 37 50
084A-7 R6 73 124 73 55 75 59 45 60
098A-7 R7 94 168 94 75 100 73 55 75
119A-7 R7 119 198 119 90 125 94 75 100
142A-7 R8 137 250 137 110 150 119 90 125
174A-7 R8 171 274 171 132 200 137 110 150
210A-7 R9 230 384 230 160 250 182 132 200
271A-7 R9 257 411 257 200 250 230 160 250
3AXD00000588487
U
N
Nominal voltage of the drive. For the input voltage range, see section Electrical
power network specification in the hardware manual.
I
1N
Nominal rms input current
I
N
Nominal output current (available continuously with no over-loading)
P
N
Typical motor power in no-overload use
I
Ld
Continuous rms output current allowing 10% overload for 1 minute every 5 minutes
P
Ld
Typical motor power in light-overload use
I
max
Maximum output current. Available for 10 seconds at start. then as long as allowed
by drive temperature.
I
Hd
Continuous rms output current allowing 50% overload for 1 minute every 5 minutes.
* Continuous rms output current allowing 30% overload for 1 minute every 5 minutes.
** Continuous rms output current allowing 25% overload for 1 minute every 5
minutes.
UL (NEC) RATINGS – ACS880-01 +C132
Drive
type
ACS880-
01-
Frame
size
Input
rating
Max.
cur-
rent
Output ratings
Light-overload use Heavy-duty use
I
1N
I
max
I
Ld
P
Ld
I
Hd
P
Hd
AA AkWhp AkWhp