ACS880-01/04 +C132 marine type-approved drives 21
Definitions – ACS880-04
UL (NEC) RATINGS – ACS880-04 +C132
Drive
module
type
ACS880-
04-
Frame
size
Input
rating
Max. current Output ratings
Light-overload use Heavy-duty use
I
1N
I
max
I
max_
start
I
Ld
P
Ld
I
Hd
P
Hd
AAAAkWhpAkWhp
U
N
= 460
503A-5 R10 478 560 671 459 315 400 343 200 300
583A-5 R10 554 730 828 544 355 450 395 250 350
635A-5 R10 603 730 954 592 400 500 453 315 400
715A-5 R11 679 850 1100 670 450 550 538 355 450
820A-5 R11 779 1020 1100 767 500 600 594 400 500
880A-5 R11 836 1100 1100 814 560 700 645 450 550
U
N
= 575 V
330A-7 R10 314 480 510 304 250 300 242 200 250
370A-7 R10 352 520 650 342 315 350 309 250 300
430A-7 R10 409 540 720 399 355 400 342** 315 350
425A-7 R11 404 520 720 394 355 400 342 315 350
470A-7 R11 447 655 830 432 400 450 394 355 400
522A-7 R11 496 685 910 480 450 500 432 400 450
590A-7 R11 561 800 1010 542 500 550 480 450 500
650A-7 R11 618 820 1100 599 560 600 542** 500 600
721A-7 R11 685 825 1100 670 630 700 542** 500 600
3AXD00000588487
U
N
Nominal voltage of the drive. For the input voltage range, see section Electrical
power network specification in the hardware manual.
I
1N
Nominal rms input current
I
N
Nominal output current (available continuously with no over-loading)
P
N
Typical motor power in no-overload use
I
Ld
Continuous rms output current allowing 10% overload for 1 minute every 5 minutes
P
Ld
Typical motor power in light-overload use
I
max
Maximum output current. Available for 10 seconds at start. then as long as allowed
by drive temperature.