102 CoriolisMaster FCB400, FCH400 CORIOLIS MASS FLOWMETER | OI/FCB400/FCH400-EN REV. E
… 9 Operation
… Parameter descriptions
Menu / parameter Description
Device Setup / ...Transmitter / ...Units
Unit Massflow Qm Selection of unit for mass flow.
Refer to Table 2: Units for mass flow on page 78.
The selection applies to the display of the current mass flow, and for the parameters related to mass flow such as QmMax
and QmMaxDN.
Unit Mass Totalizer Selection of unit for the mass counters.
Refer to Table 6: Units for the mass totalizer on page 79.
Unit Volumeflow Qv Selection of unit for volume flow.
Refer to Table 7: Units for the volume totalizer on page 79.
The selection applies to the display of the current volume flow and for the parameters related to volume flow such as
QvMax and QvMaxDN.
Unit Vol. Totalizer Selection of unit for the volume totalizers.
Refer to Table 7: Units for the volume totalizer on page 79.
Density Selection of unit for the density.
Refer to Table 3: Density units on page 78.
Unit Temperature Selection of unit for temperature.
Refer to Table 4: Temperature units on page 78.
Concentration Selection of unit for concentration measurement.
Refer to Table 5: Concentration units on page 79.
Variable 1 Name Selection of the unit for external process variables.
The transmitter can show two external process variables in the display. The process variables can be transferred from the
fieldbus master to the transmitter via the HART, Modbus or PROFIBUS DP protocol. You can configure the indicator through
the ‘Display’ menu.
Variable 2 Name
Device Setup / ...Transmitter / ...Custom Units
Mass flow Qm Name Sets the name or abbreviation of the user-defined unit for mass flow.
Mass flow Qm Factor Sets the factor of the user-defined unit for mass flow in kg / seconds.
Mass Tot. Name Sets the name or abbreviation of the user-defined unit for the mass counter.
Mass Tot. Factor Sets the factor of the user-defined unit for the mass counter in kg.
Volumeflow Qv Name Sets the name or abbreviation of the user-defined unit for volume flow.
Volumeflow Qv Factor Sets the factor of the user-defined unit for volume flow in liters/seconds.
Volume Tot. Name Sets the name or abbreviation of the user-defined unit for the volume totalizer.
Volume Tot. Factor Sets the factor of the user-defined unit for the volume totalizer in liters.
Density Name Sets the name or abbreviation for the user-defined density unit.
Density Factor Sets the factor for the user-defined density unit in liters/seconds.
Temperature Name Sets the name or abbreviation for the user-defined temperature unit.
Temperature Factor Sets the factor for the user-defined temperature unit in °C.