CoriolisMaster FCB400, FCH400 CORIOLIS MASS FLOWMETER | OI/FCB400/FCH400-EN REV. E 17
Zone 2, 21 and Division 2 – Model: FCx4xx-A2, FCx4xx-F2
Outputs on basic device Operating values (general) Type of protection – ‘nA’ / ‘NI’
U
N
I
N
U
N
I
N
Current / HART output 31 / U
CO
, active
Terminals 31 / U
CO
30 V 30 mA 30 V
30 mA
Current / HART output 31 / 32, passive
Terminals 31 / 32
30 V 30 mA 30 V
30 mA
Digital output 41 / 42, active*
Terminals 41 / 42 and V1 / V2*
30 V 30 mA 30 V
30 mA
Digital output 41 / 42, active**
Terminals 41 / 42 and U
CO
/ 32**
30 V 30 mA 30 V
30 mA
Digital output 41 / 42, passive
Terminals 41 / 42
30 V 25 mA 30 V
25 mA
Digital output 51 / 52, active*
Terminals 51 / 52 and V1 / V2*
30 V 30 mA 30 V
30 mA
Digital output 51 / 52, passive
Terminals 51 / 52
30 V 30 mA 30 V
30 mA
All outputs are electrically isolated from each other and from the power supply.
Digital outputs 41 / 42 and 51 / 52 are not electrically isolated from each other. Terminals 42 / 52 have the same potential.
* Only in conjunction with additional ‘24 V DC loop power supply (blue)’ plug-in card in slot OC1.
** Only in conjunction with current output U
CO
/ 32 in ‘Powermode’, see Current output Uco / 32 as loop power supply for digital output 41 / 42 or 51 / 52 on
page 50.
Inputs and outputs with optional plug-in cards Operating values (general) Type of protection – ‘nA’ / ‘NI’
U
N
I
N
U
N
I
N
Current output V3 / V4, active*
Terminals V3 / V4 and V1 / V2*
30 V 30 mA 30 V 30 mA
Current output V1 / V2, passive**
Current output V3 / V4, passive**
Terminals V1 / V2** or V3 / V4**
30 V 30 mA 30 V 30 mA
Digital output V3 / V4, active*
Terminals V3 / V4 and V1 / V2*
30 V 25 mA 30 V 25 mA
Digital output V1 / V2, passive**
Digital output V3 / V4, passive**
Terminals V1 / V2** or V3 / V4**
30 V 30 mA 30 V 30 mA
Digital input V3 / V4, active*
Terminals V3 / V4 and V1 / V2
30 V 3.45 mA 30 V 3.45 mA
Digital input V1 / V2, passive*
Digital input V3 / V4, passive*
Terminals V1 / V2** or V3 / V4**
30 V 3.45 mA 30 V 3.45 mA
Modbus® / PROFIBUS DP®
Terminals V1 / V2
30 V 30 mA 30 V 30 mA
* Only in conjunction with additional ‘24 V DC loop power supply (blue)’ plug-in card in slot OC1.
** The terminal assignment depends on the model number or the slot assignments. For connection examples, see Connection examples on page 53.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB CoriolisMaster FCH400 Series and is the answer not in the manual?

ABB CoriolisMaster FCH400 Series Specifications

General IconGeneral
BrandABB
ModelCoriolisMaster FCH400 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals