26 CoriolisMaster FCB400, FCH400 CORIOLIS MASS FLOWMETER | OI/FCB400/FCH400-EN REV. E
… 3 Design and function
Device designs
1 Sensor (integral mount design, dual-compartment housing)
2 Sensor (integral mount design, single-compartment housing)
3 Sensor (remote mount design)
Figure 4: Designs
Sensor
Model FCB400 standard design FCH400 hygienic design
Housing Integral mount design, remote mount design
Measuring accuracy for liquids FCB430 FCB450 FCH430 FCH450
Mass flow* 0.4 %, 0.25 % and 0.2 % 0.1 % and 0.15 % 0.4 %, 0.25 % and 0.2 % 0.1 % and 0.15 %
Volume flow* 0.4 %, 0.25 % and 0.2 % 0.15 % and 0.11 % 0.4 %, 0.25 % and 0.2 % 0.15 % and 0.11 %
Density 0.01 kg/l
• 0.002 kg/l
• 0.001 kg/l (optional)
• 0.0005 kg/l
0.01 kg/l
• 0.002 kg/l
• 0.001 kg/l (optional)
• 0.0005 kg/l
Temperature 1 K 0.5 K 1 K 0.5 K
Measuring accuracy for gases* 1 % 0.5 % 1 % 0.5 %
Permissible measuring medium
temperature T
medium
−50 to 160 °C
(−58 to 320 °F)
−50 to 205 °C
(−58 to 400 °F)
−50 to 160 °C
(−58 to 320 °F)
−50 to 205 °C
(−58 to 400 °F)
Process connection
Flange DIN 2501 / EN 1092-1 DN 10 to 200; PN 40 to PN 160 —
Flange ASME B16.5 DN ½ to 8 in; CL150 to CL1500 —
JIS flange DN 10 to 200; JIS 10K to 20K —
Pipe fitting DIN 11851 DN 10 to 100 (⅜ to 4 in) DN 15 to 100 (½ to 4 in)
Pipe fitting SMS 1145 DN 25 to 80 (1 to 3 in) —
Tri-clamp DIN 32676 (ISO 2852)
Tri-clamp BPE
DN 15 to 100 (¼ to 4 in)
DN ⅜ to 4 in
DN 20 to 100 (¼ to 4 in)
DN ⅜ to 4 in
Female thread DIN ISO 228 and
ASME B 1.20.1
DN 15; PN 100 —
Other connections On request On request
Wetted material Stainless steel 1.4435 or 1.4404 (AISI 316L), nickel-alloy
C4 / C22 (optional)
Stainless steel, polished 1.4404 (AISI 316L) or 1.4435 (AISI
316L)
IP rating • Integral mount design: IP 65 / IP 67, NEMA 4X
• Remote mount design: IP 65 / IP 67 / IP 68 (sensor only, immersion depth: 5 m), NEMA 4X
Approvals
• Explosion protection ATEX / IECEx / cFMus ATEX / IECEx / cFMus
• Hygiene approvals — EHEDG, FDA compliant
• Legal metrology Type-tested for legal metrology in accordance with MID / OIML R117 or API / AGA
• Further approvals At www.abb.com/flow or upon request.
* Indication of accuracy in % of the measured value