CoriolisMaster FCB400, FCH400 CORIOLIS MASS FLOWMETER | OI/FCB400/FCH400-EN REV. E 27
1 Dual-compartment housing
2 Single-compartment housing
Figure 5: Transmitter with remote mount design
Transmitter
Housing Integral mount design (see Figure 4, pos.
and
), remote mount design.
IP rating IP 65 / IP 67, NEMA 4X
Cable length Maximum 200 m (656 ft), with remote mount design only
Power supply 100 to 240 V AC, 50 / 60 Hz
11 to 30 V DC, nominal voltage: 24 V DC
Outputs in basic version Current output: 4 to 20 mA active or passive
Digital output 1: passive, configurable as pulse, frequency or switch output
Digital output 2: passive, configurable as pulse or switch output
Additional optional outputs The transmitter has two slots in which plug-in cards can be inserted to provide additional inputs and
outputs. The following plug-in cards are available:
• Current output (maximum two plug-in cards simultaneously)
• Digital output (maximum one plug-in card)
• Digital input (maximum one plug-in card)
• Modbus or PROFIBUS DP interface (maximum of one plug-in card)
• 24 V DC loop power supply for active outputs (maximum one plug-in card)
External output zero return Yes
External totalizer reset Yes
Forward / reverse flow metering Yes
Counter Yes
Communication HART® protocol 7.1, Modbus® or Profibus DP® (using a plug-in card)
Empty pipe detection Yes, via configurable density alarm
Self-monitoring and diagnosis Yes
Local indicator Yes
Field optimization for flow and density Yes
Concentration measurement ‘DensiMass’ Yes, optional on models FCB450 and FCH450
‘FillMass’ filling function Yes, optional on models FCB450 and FCH450
‘VeriMass’ function Yes, optional
Change from one to tw o columns