EasyManua.ls Logo

ABB DWTL1 - Technical Features

ABB DWTL1
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
English
- 3 -
User manual DWTL1
TECHNICAL FEATURES
Power supply: 230 Vac (-15% ÷ +10%) 50/60 Hz
Power consumption: 6 VA (2W)
Output: 1 monostable relay with change-over contact from
16 (10) A / 250 Vac
Parameters of the twilight probe:
- threshold: 3 ÷ 500 lux
- hysteresis: 1 ÷ 50 lux
- delay: 1 second ÷ 30 minutes
Minimum interval for nighttime switchings off: 30 minutes
Summer/winter time automatic update (removable)
Active backlighting of the display with mains power
Replaceable backup battery of CR2032 type
Terminals for cables with maximum cables section of 2.5 mm2
Storable programs: 120
Bluetooth BLE 4.2 communication interface (active with mains
power supply)
Operating frequency band: 2400-2483.5 MHz
Maximum transmitted radiofrequency power: 4 dBm
Operating temperature: -20 ÷ +50 °C
Operating temperature of the twilight probe: 0 ÷ +50 °C
Storage temperature: -25 ÷ +70 °C
Storage temperature of the twilight probe:-20 ÷ +70 °C
Operating humidity: 20÷90% non condensing
Container: 2 DIN modules
Protection degree: IP20
Protection degree of the twilight probe: IP65
Insulation: reinforced between accessible parts (front)
and all the other terminals

Related product manuals