Operation Manual / 4 Product description / A130-H.. - A140-H
5 Operation and service / 5.2 Service work
© Copyright 2017 ABB. All rights reserved. HZTL4030_EN Revision D May 2017
5.2.1 Service work every 25 … 50 hours
CAUTION
Unknown operational changes
Impairment to the degree of a possible operating failure can be the con-
sequence.
u Have any unknown causes clarified by an ABB Turbocharging Service Sta-
tion.
u Visual check for air, exhaust gas, water and oil leaks.
u Record operating data and enter in the engine logbook.
u In case of deviations, determine the cause.
5.2.2 Service work at 100 hours after commissioning
u Clean or replace the oil filter located in the supply pipe to the turbocharger while the en-
gine is stopped.
5.2.3 Service work according to instructions of enginebuilder
u Clean or replace the oil filter located in the supply pipe to the turbocharger while the en-
gine is stopped.
5.2.4 Service work according to data on the rating plate
(Usually after 8000 … 12000 operating hours)
The rotor and bearing parts must be checked and assessed by an ABB Turbocharging Service
Station. The following work can be carried out as preparation.
u Remove the turbocharger from the engine and disassemble according to chapter Disas-
sembly and assembly. Measure clearances.
u Clean nozzle ring, turbine casing, and compressor casing, and check for cracks and
erosion/corrosion.
Page 34 / 91