3 Calibration
3.17. Updating revolution counters
3HAC 022907-001 Revision: -74
Storing the revolution counter setting with the FlexPendant
This procedure details the second step when updating the revolution counter; storing the
revolution counter setting with the FlexPendant (RobotWare 5.0).
6. Press OK again to confirm and start the update.
CANCEL returns to the Revolution Counter Update window.
7. At this point, it is recommended that the revolution counter
values are saved to a diskette.
Not required.
8.
-
Caution!
If a revolution counter is incorrectly updated, it will cause
incorrect robot positioning, which in turn may cause damage or
injury!
Check the calibration position very carefully after each update.
How to perform the check is detailed in section Checking the
calibration position on page 23.
Step Action Note
Step Action
1. On the ABB menu, tap Calibration.
All mechanical units connected to the system are shown along with their calibration
status.
2. Tap the mechanical unit in question.
A screen is displayed: tap Rev. Counters.
en0400000771