2.5.4 Grounding Probes (2 required)
The grounding probe shown in Figure 2-8 can be substituted for grounding rings in many applications
when non-conductive or electrically insulated pipe is used. The pipeline must be drilled and tapped
as shown in Figure 2-8, with the grounding probes installed adjacent
to each of the pipeline mounting
flanges. Connect a grounding strap or wire from each probe to the meter flanges.
FIGURE 2-8. GROUNDING PROBE (OPTIONAL)
TABLE 2-3. GROUNDING PROBE PART NUMBERS
BASIC PART
NUMBER
PROBE
MATERIAL
PART NUMBER SUFFIX*
316 SS Hastalloy C Alloy 20 Hastalloy B
650B010___ T60 H20 V70 H10
* Add suffix to basic part number to complete the part number, e.g., 650B010H20 for a Hastalloy C
Grounding Probe.