Data Access in one block ordered by data type

required to read all monitoring data, and only one request is necessary to write all command data.
Monitoring Data
This address map shows how the complete monitoring data from up to four UMCs can be read in one block. The data is
ordered without any gaps after each other in the following way.
DI

DI







... AI

Diag

... Diag

The following table shows in detail how the data is organized:
UMC at
port 1
UMC at
port 2
UMC at
port 3
UMC at
port 4
Data

dec


dec


dec


dec

Summary
Warning
Summary

Local
Control
Rev
Lockout
Time

warning


 Run Rev/
Closing















dec


dec


dec


dec

Motor current in % of I
e


dec


dec


dec


dec



dec


dec


dec


dec

Analog word (Time to trip in seconds)

dec


dec


dec


dec

Analog word (Time to restart in seconds)

dec


dec


dec


dec

Analog word (Active power in selected scale)

dec


dec


dec


dec

       
Run Time


Position
Torque

Torque
Closed
End Pos

End Pos
Closed

dec


dec


dec


dec

U Imbal.
warn
U Imbal.
trip

voltage
warn

voltage
trip

power
warn

power trip

power
warn

power trip
Earth fault
warning
Earth fault
trip
Cooling
time
running
THD
warning
No start
possible

left
More than
one start
left

dec


dec


dec


dec


missing
PTC wiring
failure
PTC hot 
therm.
mode
Locked
rotor
Phase
imbalance
Phase loss Thermal

Actuator
problem

test erro
Earth fault

warning
Eart fault
trip

threshold

threshold
I <
warning
threshold
I < trip
threshold

dec


dec


dec


dec

Trip/
Warning
from


Trip/
Warning
from


Trip/
Warning
from


Trip/
Warning
from


Trip/
Warning
from


HW fault

module
Custom

tion error

missing
Trip
triggered
from
Multif.

Trip
triggered
from
Multif.

Trip
triggered
from
Multif.

Trip /
Warning
from



dec


dec


dec


dec

THD
Warning

out of
spec

power
Underload
power
Cooling
Time
Running

start left
Num
Starts


dec


dec


dec


dec


diagnosis
is
available.
Parameter
out of
range

27 UNIVERSAL MOTOR CONTROLLER UMC100.3 | MTQ22-FBP.0 MODBUS TCP MANUAL