EasyManua.ls Logo

ABB NE810 - Operating and Storage Environments

ABB NE810
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24 3BSE080633
Pulsed
magnetic eld
EN 61000-4-9 Enclosure 300
A/m
Radiated RF
immunity
EN 61000-4-3 Enclosure
10 V/m @ (80 – 800) MHz
20 V/m @ (800 – 1000) MHz
10 V/m @ (1400 – 2100) MHz
5 V/m @ (2100 – 2500) MHz
1 V/m @ (2500 – 2700) MHz
1 kHz sine, 80% AM
Conducted RF
immunity
EN 61000-4-6 Power port
10 V, 80% AM, 1 kHz; (0.15 – 80)
MHz
Signal ports
10 V, 80% AM, 1 kHz; (0.15 – 80)
MHz
Earth port
10 V, 80% AM, 1 kHz; (0.15 – 80)
MHz
Radiated RF
emission
EN 55022 Enclosure Class A
FCC Part 15 Class A
Conducted RF
emission
EN 55022 Power port Class B
Signal ports Class B
Dielectric
strength
EN 60950-1
Power port to all
other ports
1.5 kVrms, 50 Hz, 1 min
Signal ports to
all other ports
1.5 kVrms, 50 Hz, 1 min
Environmental
Temperatures
Operating –40 to +70°C (–40 to +158°F)*
Storage and
transport
–50 to +85°C (–58 to +185°F)
Humidity Operating 5 to 95% relative humidity
Storage and
transport
5 to 95% relative humidity

Related product manuals