EasyManuals Logo

ABB NextMove e100 Quick Installation Guide

ABB NextMove e100
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #47 background imageLoading...
Page #47 background image
Snabbinstallationshandbok – NextMove e100 47
X8, X9, X10 - Digitala ingångar
X12 - Analoga ingångar
X12 - Reläutgång
X13 - Analoga utgångar
Description Unit Value
Type Opto-isolated
USR V+ supply voltage
Nominal
Minimum
VDC
24
12
Input voltage
Active
Inactive
VDC
> 12
< 2
Input current
(maximum per input, USR V+ = 24 V)
mA 7
Sampling interval ms 1
Description Unit Value
Type Differential
Common mode voltage range V DC ±10
Input impedance 120
Maximum input current mA 4.9
Input ADC resolution bits 12 (includes sign bit)
Equivalent resolution (±10 V input) mV ±4.9
Sampling interval µs 500 (both inputs enabled)
250 (one input disabled)
All models Unit All models
Contact rating (resistive) 1 A @ 24 V DC
or
0.25 A @ 30 V AC
Operating time (max) ms 5
Description Unit Value
Type Bipolar
Output voltage range V DC ±10
Output current (per output) mA 2.5
Output DAC resolution bits 12
Equivalent resolution mV ±4.9
Update interval ms 1
LT0305A01.book Page 47 Wednesday, June 21, 2017 2:10 PM

Other manuals for ABB NextMove e100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB NextMove e100 and is the answer not in the manual?

ABB NextMove e100 Specifications

General IconGeneral
BrandABB
ModelNextMove e100
CategoryController
LanguageEnglish

Related product manuals